Graco MAGNUM XR5 Operating Instructions Manual

Graco MAGNUM XR5 Operating Instructions Manual

Xr series airless sprayers model 232740,model 232745,model 232750
Hide thumbs Also See for MAGNUM XR5:

Advertisement

Operating Instructions

This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
INSTRUCTIONS
t
M
XR9, Model 232750, Series A
AGNUM
0.38 gpm (1.44 lpm) sprayer on heavy-duty deluxe cart, 50 ft (15.2 m) hose, and
SG3 pro metal gun with reversible tip and guard
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
M
XR7, Model 232745, Series A
AGNUM
0.31 gpm (1.17 lpm) sprayer on heavy-duty cart, 50 ft (15.2 m) hose, and
SG2 metal gun with reversible tip and guard
3000 psi (21 MPa, 207 bar) Maximum Working Pressure
M
XR5, Model 232740, Series A
AGNUM
0.24 gpm (0.91 lpm) stand-mount sprayer, 25 ft (7.6 m) hose, and
SG1 gun with reversible tip and guard
2800 psi (19 MPa, 193 bar) Maximum Working Pressure
Features of every M
AGNUM
D 120V, permanent magnet, open-frame DC motor
D Power Flusht cleaning (for flushing with water)
D XR Power-Pistont hardened stainless steel pump
D Demand Deliveryt system (pump stops when
spraying stops)
D InstaCleant filter system
M
XR5
AGNUM
Model 232740
XR Series Airless Sprayers
sprayer
9557A
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
ECOPYRIGHT 1999, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
To find your Graco/M
D See the enclosed Graco/M
D Visit our website at www.graco.com
D Call us at 1–888–541–9788
9558A
M
XR7
AGNUM
Model 232745
Form No. 309043
authorized service center
AGNUM
Authorized Service Centers list
AGNUM
M
AGNUM
Model 232750
Rev. G
9559A
XR9

Advertisement

Table of Contents
loading

Summary of Contents for Graco MAGNUM XR5

  • Page 1: Operating Instructions

    D Demand Deliveryt system (pump stops when spraying stops) D InstaCleant filter system 9557A 9558A 9559A AGNUM AGNUM AGNUM Model 232740 Model 232745 Model 232750 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ECOPYRIGHT 1999, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D Do not smoke in spray area. Make sure gun is assembled with correct D Use only M or Graco airless paint hoses. AGNUM gasket for fluid being sprayed. See Instal- D Use outdoors or in a well-ventilated area.
  • Page 3: Table Of Contents

    Section Page Component Identification and Function ....Preparing to Spray ........Pail Flushing .
  • Page 4: Component Identification And Function

    Component Identification and Function 9558A AGNUM Connect cart handles on XR7 and XR9 as follows: 1. Remove thumbscrews and bolts from cart frame. 2. Position handle on frame as shown, and align bolt holes in handle with bolt holes in frame. 3.
  • Page 5 Component Identification and Function Electric motor (inside of shroud) Provides mechanical power to pump Power switch For manually turning on/off electrical power to motor (“I” is ON / “0” is OFF) Pressure Control knob For manually increasing (turn clockwise) and decreasing (turn counter-clockwise) fluid pressure in pump, hose, and gun Pump fluid outlet fitting Threaded connection for paint hose...
  • Page 6: Preparing To Spray

    Preparing to Spray For Setup, Priming, and Installing Tip & Guard instructions, see the enclosed Operator’s Quick Guide. Selecting a Tip Hole Size Tips come in a variety of hole sizes for a range of fluids. Your M sprayer includes the tip most likely to satisfy AGNUM common spraying applications.
  • Page 7 Preparing to Spray Using the Right Tip for the Job Understanding the Tip Number Consider the coating and the surface to be sprayed. The last three digits of the tip number (example: Make sure you use the best tip hole size for that coating RST413) contain information about the hole size and and the best fan width for that surface.
  • Page 8: Pail Flushing

    Pail Flushing FLUSH WARNING 2. Align the bucket symbol on the pressure control knob and the arrow on the sprayer. Trigger gun into Fire and Explosion waste pail to relieve pressure that might be in hose. on page 2. Hazard NOTE: To minimize splashing, aim gun at inside wall of Fluid Injection Hazard empty waste pail.
  • Page 9 Pail Flushing Step 6 is for getting the paint in the hose back into the FLUSH paint container. A 50-foot (15 m) section of hose holds approximately 1 quart (1 liter) of paint. 10. Clean tip & guard assembly and gun filter with water 6.
  • Page 10: Troubleshooting

    Troubleshooting Check everything in this Troubleshooting table before you bring the sprayer to a Graco authorized service center. For Basic Troubleshooting , see the enclosed Operator’s Quick Guide. PROBLEM CAUSE SOLUTION Power switch (B) is on and Motor or control is damaged.
  • Page 11 Fan pattern varies dramatically Pressure control switch is worn Return sprayer to Graco authorized service center. while spraying or sprayer does and causing excessive not turn on promptly when pressure variation. resuming spraying.
  • Page 12: Maintenance And Service

    Maintenance and Service Pump Check Valves CAUTION Inadequate flushing of paint can Protect the internal drive parts of this sprayer from water. cause the inlet valve check balls to Openings in the shroud allow for air cooling of the mechanical stick to the seats.
  • Page 13: Technical Data

    Technical Data AGNUM AGNUM AGNUM Working pressure range 0 to 2800 psi 0 to 3000 psi 0 to 3000 psi (0 to 19 MPa, 0 to 193 bar) (0 to 21 MPa, 0 to 207 bar) (0 to 21 MPa, 0 to 207 bar) Electric motor (open-frame, 5.8 Amp 5.8 Amp...
  • Page 14: Accessories

    Accessories Airless Spray Guns 243010 SG1 gun Reversible Tip Selection Chart With 413 reversible tip and guard Maximum tip hole size that each M sprayer AGNUM 243011 SG2 metal gun supports is as follows: With 515 reversible tip and guard XR5: New 0.015 in.
  • Page 15 Accessories Extension Adapters Gun Filters 243055 Gun adapter For removing debris from paint Fits 11/16 in. (17 mm) gun to provide a to reduce tip clogging and improve 7/8 in. (22 mm) thread finish 243056 Easy Turnt 180_ directional spray nozzle 243076 For SG1 gun, 2-pack Attaches to heavy-duty extension or spray...
  • Page 16: Limited Warranty

    This warranty does not cover and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by improper use, accidents, user negligence, use of non-Graco component parts or service or repair performed by anyone other than a Graco authorized service center.

This manual is also suitable for:

Magnum xr7Magnum xr9

Table of Contents