Parameter
25.
RESOL
26.
S/WARE
27.
QUIT
212-M-V2.1
Value
NORM
Display Energy, Volume and Tempera-
tures with normal resolution.
HIGH
Display Energy, Volume and Tempera-
tures with high resolution for testing
purposes (EN1434-2).
Volume will be displayed as floating point
values in Joule and m 3 units respectively.
Temperatures will be displayed with two
decimal places.
x.xx
Software revision number.
YES
NO
Description
Return to normal operation upon
pressing the DISPLAY key.
Continue in the Check Set-up mode.
To continue use the <key to select
NO and then press the DISPLAY key .
Operation