Function Overview - Victron energy BMV-600 Manual

Precision battery monitor
Hide thumbs Also See for BMV-600:
Table of Contents

Advertisement

2.5

Function overview

The BMV factory settings are suitable for an average 12V/24V lead
acid battery system of 200Ah. The BMV can automatically detect the
nominal voltage of the battery system (see chapter 3.3), so in most
cases the only setting which will need to be changed is the battery
capacity (Cb). When using other types of batteries please ensure that
all the relevant specifications are known before attempting to setup the
BMV parameters.
2.5.1
Setup parameter overview
Name
Description
Cb
Battery capacity
Vc
Charged voltage
It
Tail current
Tcd
Charged detection time
CEF
Charge efficiency factor
PC
Peukert exponent
Ith
Current threshold
Tdt
Time to go tA
DF
Discharge floor (SOC relay)
ClS
Clear SOC relay
RME
Relay minimum enable time
RDD
Relay disable delay
Al
Alarm low voltage (buzzer)
Alc
Clear low voltage alarm
Ah
Alarm high voltage (buzzer)
Ahc
Clear high voltage alarm
AS
Alarm low SOC (buzzer)
ASc
Clear low SOC alarm
Rl
Relay low voltage
Rlc
Clear relay low voltage
Rh
Relay high voltage
Rhc
Clear relay high voltage
BLI
Backlight intensity
D V
D VS*
The quantity with an 'x' can
D I
be selected in display
mode. When they are all
D CE
clear, the SOC is displayed.
D SOC
D TTG
ZERO
Zero current calibration
SYNC
Manual synchronization
R DEF
Reset default values
Cl HIS
Clear history
LOCK
Setup lock
SW
Firmware version (cannot
be altered)
* BMV-602 Only
Min.
Default
20
200
0.0
13.2
0.5
4.0
1
3
50
90
1.00
1.25
0.00
0.01
0
3
0.0
50.0
0.0
90.0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
5
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
No
No
N/A
N/A
www.victronenergy.co
Max.
Resolutio
n
9999
1
90.0
0.1
10.0
0.1
50
1
99
1
1.50
0.01
2.00
0.01
12
1
99.0
0.1
99.0
0.1
500
1
500
1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
95.0
0.1
9
1
Yes
N/A
Yes
N/A
Yes
N/A
Yes
N/A
Yes
N/A
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Yes
N/A
N/A
N/A
m
Units
Ah
V
%
min.
%
A
min.
%
%
min.
min.
V
V
V
V
%
%
V
V
V
V
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bmv-602Bmv 600Bmv-600sBmv-600hsBmv-602s

Table of Contents