Predator 63078 Owner's Manual & Safety Instructions page 15

13500 watts
Table of Contents

Advertisement

Battery Setup Instructions
1. Place a fully charged, lead-acid 12 volt,
36  A h battery (not included) in a stable,
flat location near the engine.
2. Use provided battery cables only.
3. Attach the positive cable securely to
the positive battery terminal to prevent
disconnection and short circuits.
Grounding
1. The Generator must be properly grounded
before operation. Have the unit grounded by a
qualified electrician if you are not qualified to do so.
2. To ground the Generator, connect a #4 AWG
grounding wire (not included) from the
Grounding Terminal on the Control Panel
to a grounding rod (not included) that has
been driven at least 24 inches deep into the
earth. The grounding rod must be an earth-
driven copper or brass rod (electrode) which
can adequately ground the Generator.
3. WARNING! GFCI receptacles will not protect
from electric shock if Generator is not grounded.
ITEM 63078
For technical questions, please call 1-888-866-5797.
4. Attach the negative cable securely to
the negative battery terminal to prevent
disconnection and short circuits.
5. Coat the terminals and cable ends with
a corrosion-preventive coating.
NOTICE: This Generator is not intended to power
sensitive electronic equipment without the addition
of an appropriate line conditioner and surge
protector (both not included). Sensitive electronic
equipment includes, but is not limited to,
audio/video equipment, some television sets,
computers, and printers. Sensitive electronic
equipment should be operated on approved inverter-
type generators or pure sine wave generators.
4. Refer to local regulations for
ground source information.
Page 15