Store the nose adapter in place when not in use. The
place for storage is on both sides of the tool and inside
the carrying case.
1
2
007186
Connecting air hose
1
007187
Slip the air socket of the air hose onto the air fitting on the nailer.
Be sure that the air socket locks firmly into position when
installed onto the air fitting. A hose coupling must be installed
on or near the tool in such a way that the pressure reservoir will
discharge at the time the air supply coupling is disconnected.

OPERATION

To drive a nail, you may place the contact element
against the workpiece and pull the trigger.
007188
CAUTION:
WITH THE TRIGGER HELD IN A HALF-PULLED
POSITION, an unexpected nailing could occur, if contact
element is allowed to re-contact against the workpiece
or the other surface under the influence of recoil.
In order to avoid this unexpected nailing, perform
as follows;
A.
Do not place the contact element against the
workpiece with excessive force.
B. Pull the trigger fully and hold it on for 1-2 seconds
after nailing.
1. Nose adapter
2. Place for
storage
1. Air fitting
2
2. Air socket
Direction of exhaust air
007189
The direction of exhaust air can be changed 360 degrees
of angle by turning the exhaust cover with a hand.
Removing nails
CAUTION:
Do not use deformed nails or nail strip. Failure to
do so causes poor nail feeding.
WARNING:
Always disconnect the hose before removing nails.
Open the slide door and remove nails from the
magazine.
007190
With the slide door kept open, open the door and take
out nails.
Removing the contact top allows nails to be easily taken
out. When re-installing the contact top, insert the
prorusion of the contact top into the notch in the contact
arm.
1
007191
7
1. Exhaust cover
1
1. Latch