Approved UL913, For Class 1, Division 1, Groups C & D hazardous locations when used with alkaline batteries. Warning: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. 7-11 UL V4 Sensit® is a registered trademark of J And N...
CONTENTS GENERAL DESCRIPTION Page # 1. Accessories and Parts The Sensit® HXG-3 is designed to detect combustible gases. All 2. General Description Sensit® HXG-3 instruments incorporate an advanced low power 2. Specifications semiconductor sensor to measure combustible gases in LEL (Lower 3.
LED on the right side will flash and an audible warning will sound. There are 3 operational button pads on the front of all Sensit® Sensit® HXG-3 instruments are constructed of durable ABS HXG-3 instruments.
Combustible Gas Sensor tery compartment the batteries can come out. Observe the po- All Sensit® HXG-3 instruments incorporate a highly sensitive larity markings on the inside of the battery holder. Improper in- semiconductor type sensor. The function and accuracy of the stallation will cause the instrument not to operate.
OPERATION AND USE OPERATION AND USE continued from page 7 CAUTION: Always start any Sensit® HXG-3 in a gas 4. Model 3.30 displays LEL% only. Model 3.35 displays LEL% free environment to insure a proper zero. and ppm. All LEL readings have a resolution of 0.1% LEL or 50ppm methane.
CALIBRATION CHECK the tick becomes a steady tone rotate the thumbwheel in a To verify the accuracy of any Sensit® HXG-3, it must be ex- clockwise direction while keeping the sensor in the same posi- posed to a known concentration of test gas. Any sensor that tion.
MENU continued from page 11 (C) to scroll to another PRINT MENU function. Pressing the The Sensit® HXG-3 has several features in the user menu. POWER/MUTE button (A) will reenter the USER MENU. Use These include: the SAVE/ZERO button (C) at this time to scroll to another PRINT MENU: SESSION LOG - print data that was saved.
Page 8
USER MENU. Pressing the POWER/MUTE button (A) will re- number of stored session log saves is factory set at 6. It can turn the instrument to the working display. store up to 100 by changing a factory setting (contact SENSIT SHOW CAL LOG TECHNOLOGIES for instructions).
Page 9
NOTE: Using calibration kits other than recommended by the Smart-Call Station to be performed. At the end of the test SENSIT TECHNOLOGIES may cause inaccurate readings. the instrument will beep 3 times and display PASS or FAIL. Repairs are required if any sensor fails o calibrate.
WARRANTY AND REPAIR POLICY CALIBRATION continued from page 16 Your Sensit® HXG-3 is warranted to be free from defects in press and holding the (C) button until the display shows materials and workmanship for a period of two years after pur- AUTOZERO.