Sensit HXG-2d Instruction Manual

Sensit HXG-2d Instruction Manual

Combustible gas detector
Hide thumbs Also See for HXG-2d:

Advertisement

WARRANTY AND REPAIR POLICY
®
Your SENSIT
HXG-2d instrument is warranted to be free from
defects in materials and workmanship for a period of two years
after purchase (excluding sensor, calibration and batteries). If
within the warranty period your instrument should become inop-
erative from such defects, the unit will be repaired or replaced at
our option. This warranty covers normal use and does not cover
damage which occurs in shipment or failure which results from
alteration, tampering, accident, misuse, abuse, neglect, or im-
proper maintenance. A purchase receipt or other proof of date of
original purchase will be required before warranty performance
will be rendered. Instruments out of warranty will be repaired for
a service charge. Return the unit postpaid and insured to:
SENSIT TECHNOLOGIES
851 Transport Drive
Valparaiso, IN 46383
This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
MADE IN USA
#750-00022 Instruction Manual
10-30-09 Revised 3-27-14 V5
SENSIT® HXG-2d
Combustible Gas Detector
INSTRUCTION MANUAL
Read and understand Instructions before use.
710183
UL 913
Intrinsically Safe for Use in
Class I, Groups C and D, T3
Hazardous Locations
AEx ia IIB T3
IP20
For use in clean dry areas only.
Suitable for combustible gases
such as Methane, Butane, Propane
and Natural Gas

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HXG-2d and is the answer not in the manual?

Questions and answers

Summary of Contents for Sensit HXG-2d

  • Page 1 WARRANTY AND REPAIR POLICY Combustible Gas Detector ® Your SENSIT HXG-2d instrument is warranted to be free from INSTRUCTION MANUAL defects in materials and workmanship for a period of two years Read and understand Instructions before use. after purchase (excluding sensor, calibration and batteries). If...
  • Page 2: Table Of Contents

    WARNING: All Accessories are to be used in an area known to be Optional Accessories and Parts non-flammable. Extension Adapter 870-00012 WARNING: Use only sensor from SENSIT Technologies. PN 375-2611-01 Calibration Kit 2.5% Methane 881-00017 Calibration Kit .5% Methane 881-00075...
  • Page 3: General Description

    GENERAL DESCRIPTION SPECIFICATIONS SENSOR SPECIFICATIONS The Sensit® HXG-2d is designed to detect combustible gases. TYPE RESOLUTION RANGE ACCURACY This instrument incorporates an advanced low power semicon- 10ppm 0-990ppm ±10% ductor sensor to measure a wide variety of combustible gases 0.1% 0-100%LEL ±10%...
  • Page 4: Sensor Type

    PRODUCT FEATURES continued from page 5 continued from page 6 Sensit® HXG-2d instruments are constructed of durable high There are 3 operational button pads on the front of all impact ABS to withstand the rigors of field use. Sensit® HXG-2d instruments.
  • Page 5: Battery Installation

    BATTERY INSTALLATION/REPLACEMENT OPERATION AND USE WARNING: Always change batteries in an environment CAUTION: Always start any Sensit® HXG-2d in a gas free free of combustible gases. environment to ensure a proper zero. 1. Push and hold the power button (A) until the display and backlight WARNING: Do not mix batteries of different type or age.
  • Page 6 OPERATION AND USE OPERATION AND USE continued from page 8 continued from page 10 4. All instruments read with a resolution of 10ppm up to 990ppm. NOTE: These instruments have cross sensitivities to a variety of gases. The scale automatically switch to LEL when 990ppm is exceeded with a resolution of 0.1% LEL.
  • Page 7: Calibration Check

    CALIBRATION CHECK CALIBRATION continued from page 12 To verify the accuracy of any Sensit® HXG-2d it must be ex- Step 3: Attach the adapter to the sensor cap assembly. posed to a known concentration of test gas. Any sensor that...
  • Page 8: Sensor Replacement

    2-60% WARNING: Substitution of components may impair intrinsic safety. Show PPM 10PPM Resolution WARNING: Use only sensor from SENSIT Technologies. The Above settings are field adjustable: Part Number 375-2611-01 Setting Display Mode For %LEL & Alarm Setpoint For %LEL While the unit is on and in the working display, push the A and C buttons until the display shows OPt.

Table of Contents