4.1.1
ACT/ACU 201
Recommended
motor shaft output
Nominal voltage
Energy dissipation,
heat sink [2 kHz]
Energy dissipation,
interior
Thermal resistance
Dimensions
Heat sink
T
–T
k max
4.1.2
ACT/ACU 201
Recommended
motor shaft output
Nominal voltage
Energy dissipation,
heat sink [2 kHz]
Energy dissipation,
interior
Thermal resistance
Dimensions
Heat sink
T
–T
k max
10

ACT/ACU 201 (0.55 to 3.0 kW, 230 V)

P
kW
V
U
W
P
v
W
P
v int
R
K/W
th
mm
HxWxD
HxW mm
ΔT
K
U

ACT/ACU 201 (4.0 to 9.2 kW, 230 V)

P
kW
V
U
W
P
v
W
P
v int
R
K/W
th
mm
HxWxD
HxW mm
ΔT
K
U
Type designation
-05
-07
-09
Motor-side output
0.55
0.75
1.1
Mains-side input
43
53
73
12
15
18
Thermal resistance
0.93
0.75
0.55
Mechanical
190x82x140
170x82
Type designation
-18
-19
Motor-side output
4.0
5.5
Mains-side input
200
225
35
48
Thermal resistance
0.20
0.18
Mechanical
250x125x144
230x125
-11
-13
-15
1.5
2.2
3.0
230
84
115
170
21
25
31
0.48
0.35
0.24
250x85x140
230x85
40
-21
-22
7.5
9.2
230
310
420
61
68
0.13
0,10
250x150x144
230x150
40