SELF-DIAGNOSIS
DISPLAY
Mechanism
Mode Display / Head Output Drop Warning Display
This unit displays
the diagnosis
contents
of abnormalities
and the mechanism
mode on its display panel in 2-digit numbers.
When the head playback
output has dropped,
the "L" sign will be blinked.
These
display shows the outline of the problems.
Use it as a reference
when servicing
the unit.
1. Self-Diagnosis
Contents and Mechanism
Mode Display
When the STOP
button on the remote control is pressed
for about 10 seconds
continuously,
the self-diagnosis
number will be
displayed
on the display panel and number indicating the failed mechanism
mode (changed
mode when being shifted) on the tape
counter
"seconds"
display for 10 seconds
each.
During self-diagnosis
display,
displays
other than the diagnosis
number/mechanism
mode number
will be turned off and when
displays
end, the normal display will be returned
automatically.
Refer
to "Self-Diagnosis
Contents"
for the self-diagnosis
numbers
and the "Mechanism
Mode
Display
Contents"
for the
mechanism
mode numbers.
When the "0:' button on the remote control unit is pressed
during display, and clearing the self-diagnosis
display and mechanism
mode display.
Self-Diagnosis
number
Mechanism
mode number
(Tape
counter
"Seconds"
display)
Self-Diagnosis
Contents
No.
Problem
Main Possible
Cause
Mechanism
Operations
and
State
After Occurrence
00
There
is no abnormality
in the mechanism.
The cylinder
motor does not rotate.
The cylinder
motor is faulty.
Shifts to the STANDBY
mode,
and
01
The control of the cylinder
motor is
the power goes off.
faulty.
The tape winds around the cylinder.
The take-up
reel or supply reel does
Thetaleup
aorsupiW@
iscaught.
Shifts to the STANDB'f
mode.
and
02
not rotate.
The reel belt is faulty.
the power goes off.
The reel torque has decreased.
The capstan
motor does not rotate.
The capstan
motor is faulty.
03
Shifts to the STANDBY
mode,
and
The control of the capstan
motor is
the power goes off.
faulty.
The tape cannot
be loaded
with the
Error in the operations
of the tape
Unloads,
shifts to the INITIAL
mode,
cassette
inserted.
loading mechanism.
and the power goes off.
(But unloading
can be performed.)
Foreign
particles
in the tape load-
04
ing mechanism.
c The tape end sensor
is faulty.
The reel brake of the tape cassette
has not been released.
Tape
loading
and unloading
cannot
The tape guide is caught.
The power is forcibly turned
off with
05
be performed
with the cassette
in-
The loading motor is faulty.
the mechanism
at its current position.
serted.
The control of the loading
motor is
faulty.