Sanyo VHR-VX400 Service Manual page 11

Hide thumbs Also See for VHR-VX400:
Table of Contents

Advertisement

L
L
L
Note:
Set the REC/PLAY
SPEED
button to indicator panel in the
SP mode.
Self-recording
means
"Record
any broadcasting
or video
signal and playback
the just-recorded
oortion."
2-1-3.
SWITCHING
POSITION ADJ.
Measuring Point Measuring Equipment Adj. Condition
TP101
Oscilloscope
PLAY (SP) mode
(VIDEO
OUT)
Alignment
tape
TP183
VHJ-0009
(RF
SW-P)
(PM-S6)
Adj. Location
I
Adj. Value
I
REC button
CHANNEL
A (+)/7(–)
button
6.5 H * 0.5 H
PLAY button
1.
2.
3.
4.
5.
At playback
starts, press the REC button 3 times within 3
seconds
after the playback
picture comes
out. However,
these 3-push must be done within 2 seconds,
and last push
must be kept pressed
for 0.5 seconds.
(Fig. 2-1-3)
"P 000
is appeared
in FLD, and it becomes
the adjustment
mode. This indication value changes
automatically,
and 6.5
H adjustment
is done. When this value stops, adjustment
value almost becomes
6.5 H.
Obaervethe
video output signal by the oscilloscope,
triggered
by the fall down
point of RF SW PULSE
(TP183),
and
confirm that a front edge of V-SYNC
is delayed
for 6.5 H *
0.5 H from the fall down point of RF SW PULSE.
(Fig. 2-1-
4)
After the adjustment
data is fixed (it should be within 15
seconds
from the adjustment
mode start), press the PLAY
button more than 1 second. Then the indication changes
to
"P –: –", it wriies the data (delay quantity) to the E'PROM.
(If it passes through
15 seconds
before pushing the PLAY
button, the intake of the data isn't done, and it finishes the
adjustment
mode.)
If it is not in 6.5 H * 0.5 at the time of the confirmation
by the
above
3., make
manual
fine adjustment
by pressing
the
CHANNEL
button. and do the operation
of 4.
Start of play
REC button
back display
ON
I
I
'More + Adjusting
+:
,- Within 3
~l+~eign
2+lthan
I
, sees.
I
,0s
,
period
Sees.
15 sacs.
'
Fig. 2-1+
H
}
Front edge of
vertical sync elgnel
Fall
i
RF. SW PULSE
4
Fig. 2-14
2-1-4. SP STILL V-LOCK ADJ.
Measuring Point Measuring Equipment Adj. Condition
1
1
CHANNELA(+)
or~(–)
buttonlThe
minimum
vertical shake
1.
2.
3.
Set the REC/PLAY
SPEED
button to the SP mode.
Play back the own recorded portion of the tape and then set
the VCR in the STILL mode.
Press the CHANNEL
A(+) or V(–) button so that the vertical
shake
of picture becomes
its minimum.
'L
–11-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vhr-279irVhr-vx200

Table of Contents