July 15, 2025
Why when it shuts off do I still have a small blue flame in the orifice. It will go out but it takes a few minutes and it seems like the flame is in the orifice not
Gas Funnel Cake Fryer Model No. 5099NS SAFETY PRECAUTIONS DANGER Gas is safe when used properly, but can be very dangerous when used improperly. We suggest that installation be carefully made by qualified personnel only. Gas companies have competent service personnel to provide safe installation.
Page 3
Read and understand operator’s manual and all other safety instructions before using this equipment. To order copies of the operator’s manual go to gmpopcorn.com or write to Gold Medal Products Co., 10700 Medallion Drive, Cincinnati, OH 45241 USA 1-(800)-543-0862 022_060215...
Page 4
Gold Medal’s Technical Service Department at 1-800-543-0862 for any questions about your machine operations, replacement parts, or any service questions. (Gold Medal Products Co. does not assume any liability for injury due to careless handling and/or reckless operation of this equipment.) gmpopcorn.com...
To order copies of the operator’s manual go to gmpopcorn.com or write to Gold Medal Products Co., 10700 Medallion Drive, Cincinnati, OH 45241 USA 1-(800)-543-0862. Model Description 5099NS: Gas Funnel Cake Fryer Items Included with this Unit Fine Mesh Skimmer...
Page 6
Gas Funnel Cake Fryer Model No. 5099NS Setup This unit is fully assembled and has been tested at the factory. 1. Remove all packaging and tape prior to operation. 2. This unit is for outdoor use only. 3. Place the fryer in a protected location on a level, sufficiently stable base or table, where it cannot be knocked off.
Model No. 5099NS Gas Installation Instructions Gas Requirements The 5099NS is designed for Propane only. Converting this unit to an alternate fuel source will void the warranty and may cause a dangerous condition. 5099NS: Propane Gas, 95,000 BTU/HR NOTE: This fryer must be attached to a minimum of 80-100 pound LPG cylinder. The unit will not operate properly on small (20-40 lb.) cylinders.
Page 8
Gas Funnel Cake Fryer Model No. 5099NS Important Fire Safety Notice Consult your local fire protection agency for your area’s requirements. Check local fire protection requirements regularly to ensure compliance with local codes and proper operation. Have a fire extinguisher near the fryer. (Use only fire extinguishers approved for grease, oil, and electrical fires.)
Stop using the appliance immediately if damage is found, and contact a qualified professional to inspect and correct any issue. 3. Securely route all gas lines away from flames and high temperature areas. 4. Contact Gold Medal Technical Support, or a qualified Gas Service Technician with any questions. Gas Pressure We have determined that optimum frying occurs when the gas pressure is adequate.
Page 10
Gas Funnel Cake Fryer Model No. 5099NS gmpopcorn.com Page 10...
Page 11
Gas Funnel Cake Fryer Model No. 5099NS gmpopcorn.com Page 11...
Page 12
Gas Funnel Cake Fryer Model No. 5099NS gmpopcorn.com Page 12...
Page 13
Gas Funnel Cake Fryer Model No. 5099NS gmpopcorn.com Page 13...
Page 14
Gas Funnel Cake Fryer Model No. 5099NS gmpopcorn.com Page 14...
Gas Funnel Cake Fryer Model No. 5099NS OPERATING INSTRUCTIONS Controls and Their Functions GAS SAFETY VALVE The Gas Safety Valve has three settings used to control gas flow; PILOT, ON, and OFF positions. (Reference the Lighting and Shutdown Instructions in the Operating Instruction section of this manual.)
Page 16
Gas Funnel Cake Fryer Model No. 5099NS HEAT CONTROL KNOB This device controls the temperature of the cooking oil. Normal range is from 200°F to 400°F. Use an independent thermometer immersed in the oil to monitor and ensure the accuracy of the oil cooking temperature.
Gas Funnel Cake Fryer Model No. 5099NS Tank Preparation Before operating for the first time, the inside of the fryer tank should be rinsed and thoroughly dried before adding oil. See the Cleaning and Care section of this manual for cleaning instructions.
Gas Funnel Cake Fryer Model No. 5099NS Lighting and Shutdown Instructions Steps to Light the Pilot and Burner: 1. Turn the Gas Safety Valve to the PILOT position. 2. Depress the Safety Valve Button next to the safety valve handle. Hold this button down for 30-45 seconds.
Gas Funnel Cake Fryer Model No. 5099NS Operating the Fryer Important Operating Information and Quality Control Tips • Don't overheat. Don't fry if the oil temperature exceeds 400°F. • Don't waste money, use only high quality heavy duty frying shortening.
4. Add appropriate amount of dish soap. [To deep clean a tank which has a build-up of cooking oil, instead of soap, add appropriate amount of Gold Medal’s Heat’n Kleen (Item No. 2095) per amount of water used (see Heat’n Kleen product instructions)].
Gas Funnel Cake Fryer Model No. 5099NS Troubleshooting Issue Possible Cause Solution Gas Issues A. For gas issues refer to the initial Gas Setup Instructions. Cooking Issues A. Product cooking issues A. Reference the Important Operating Information and Quality Control Tips located in the Operating the Fryer section of this manual.
Gas Funnel Cake Fryer Model No. 5099NS MAINTENANCE INSTRUCTIONS DANGER Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Any alterations to this equipment will void the warranty and may cause a dangerous condition. This appliance is not intended to be operated by means of an external timer or separate remote-control system.
Gas Funnel Cake Fryer Model No. 5099NS ORDERING SPARE PARTS 1. Identify the needed part by checking it against the photos, illustrations, and/or parts list. 2. Use only approved replacement parts when servicing this unit. 3. When ordering, please include part number, part name, and quantity needed.
Gas Funnel Cake Fryer Model No. 5099NS Cabinet Exterior Part No. Item Part Description 5099NS OIL TANK WELD ASSEMBLY 89617 LEVELERS CASE 45047 HANDLE 67069 gmpopcorn.com Page 24...
Page 25
Gas Funnel Cake Fryer Model No. 5099NS Gas Line 8, 9 Part No. Item Part Description 5099NS VALVE 89014 DRAIN PLUG ASSEMBLY 89440 PILOT BURNER 74028 PILOT ORIFICE .010 LP 74050 PILOT BURNER MT BRKT 74094 U-11 BURNER 89666 1/4 IN OD ALUMINUM TUBING...
Page 26
Gas Funnel Cake Fryer Model No. 5099NS Accessories Part No. Item Part Description 5099NS TANK REGULATOR , 1/2 PSI 89245 TANK FITTING 89246 GAS HOSE (has a Flared Hose Fitting) 109000 FINE MESH SKIMMER 8055 DIAL TYPE THERMOMETER 4300 gmpopcorn.com...
Need help?
Do you have a question about the 5099NS and is the answer not in the manual?
Questions and answers
Why when it shuts off do I still have a small blue flame in the orifice. It will go out but it takes a few minutes and it seems like the flame is in the orifice not