Electrolux EKM55402X Operating And Installation Instructions page 31

Freestanding gas cooker
Table of Contents

Advertisement

INJECTOR TABLE
Gas Category: I
3B/P
Destination:PH
Class: 1
G30 28-30mbar 7.8 kW 564 g/h
RAPID BURNER
Diameter of
Injector
(1/100mm)
Nominal Rating (kW)
Consumption
SEMI-RAPID BURNER
Diameter of Injector(1/100mm)
Nominal Rating (kW)
Consumption
AUXILLARY BURNER
Diameter of Injector(1/100mm)
Nominal Rating (kW)
Consumption
OVEN BURNER
Diameter of Injector(1/100mm)
Nominal Rating (kW)
Consumption
GRILL BURNER
Diameter of Injector(1/100mm)
Nominal Rating (kW)
Consumption
Electrical Power Consumption: 220-240V ~ 50-60Hz 800-1200W
LPG
G30
30 mbar
87
3
218.1 g/h
65
1.65
120 g/h
50
1
72.7 g /h
68
2.1
153 g/h
70
2
146 g/h
30