Outdoor
Temperature Single -Paned Double-Paned
+30°F
+20°F
+10°F
0°F
-10°F
-20°F
-30°F
P
(LP) G
ROPANE
For furnaces operating on propane gas, please review the
following warnings before use.
T
O AVOID PROPERTY DAMAGE
,
DEATH
DUE TO EXPLOSION OR FIRE
DETECTING WARNING DEVICE
PROPANE GAS CAN BE REDUCED BY IRON OXIDE
GAS DETECTING WARNING DEVICE IS THE ONLY RELIABLE
METHOD TO DETECT PROPANE GAS LEAKS
I
F THE GAS FURNACE IS INSTALLED IN A BASEMENT
EXCAVATED AREA OR CONFINED SPACE
RECOMMENDED TO CONTACT A PROPANE SUPPLIER TO
INSTALL A GAS DETECTING WARNING DEVICE IN CASE OF A
.
GAS LEAK
S
INCE PROPANE GAS IS HEAVIER THAN AIR
GAS CAN SETTLE IN ANY LOW AREAS OR CONFINED
.
SPACES
P
ROPANE GAS ODORANT MAY FADE
UNDETECTABLE
A
N UNDETECTED GAS LEAK WILL CREATE A DANGER OF
. I
EXPLOSION OR FIRE
F THE PRESENCE OF GAS IS
,
SUSPECTED
FOLLOW THE INSTRUCTIONS ON THE COVER
. F
OF THIS MANUAL
AILURE TO DO SO COULD RESULT IN
SERIOUS PERSONAL INJURY OR DEATH.
T
F
HERMOSTAT
UNCTIONS
There are many types and styles of thermostats but opera-
tion is usually similar. BE SURE TO BECOME FAMILIAR
WITH YOUR THERMOSTAT. The simplest type of thermo-
stat only starts and stops the furnace to maintain the de-
sired room temperature. The most widely used types will
control both heating and cooling functions and will have a
Fan Switch with Auto and ON settings. On Auto, the circulat-
ing air blower will cycle on/off with the furnace but if switched
to ON it will run continuously regardless of whether or not
heating or cooling is being provided.
In addition, there are thermostats which automatically switch
from heating to cooling mode and those with night set back
capability. The night set back, or multiple set back, type
allows for a different temperature at night or during the day
when no one is at home. Programmable thermostats will
allow for more control and tailoring of the heating and cool-
Humidity
Glass
Glass
30%
50%
20%
40%
15%
35%
10%
30%
5%
25%
5%
20%
3%
18%
I
AS
NSTALLATIONS
WARNING
,
PERSONAL INJURY OR
,
INSTALL A GAS
. S
INCE THE ODORANT IN
(
RUST
.
WARNING
,
,
IT IS STRONGLY
,
ANY LEAKING
,
MAKING THE GAS
WARNING
ing functions. The level of this control depends on the type
of thermostat applied.
O
NLY
System
Switch
COOL
),
A
COOL
HEAT
HEAT
AN
If this furnace is a part of the Goodman ComfortNet™ family
of products, a ComfortNet thermostat may also be used to
control this furnace. This thermostat is a programmable type
that allows the setting of different temperatures during the
night and during the day. It may also be set to automatically
switch from heating to cooling. The fan switch may also be
set to ON or Auto. The ComfortNet™ system also includes
advanced set up and diagnostic features which is explained
in the ComfortNet User Manual provided with the control.
F
URNACE
E
LECTRICAL COMPONENTS ARE CONTAINED IN BOTH
COMPARTMENTS
ELECTRICAL SHOCK OR DEATH
INTERNAL COMPARTMENT COVERS
SERVICER AT ONCE IF AN ABNORMAL CONDITION IS
.
NOTICED
Keep both doors in place except for inspection and mainte-
nance. An interlock switch prevents furnace operation if the
blower door is not in place.
F
S
URNACE
1. Close the external manual gas shut-off valve.
2. Turn off the electrical power to the furnace.
3. Set the room thermostat to the lowest possible setting.
4. Remove the burner compartment door.
5
Room Temperature
Cool/Heat
Thermostat
Temperature
Control Dials
Fan Switch
Fan
Action
Switch
OFF
AUTO
None
System only cools, fan
AUTO
cycles off and on.
System only cools, fan
ON
runs all the time.
System only heats, fan
AUTO
cycles off and on.
System only heats, fan
ON
runs all the time.
No heating or cooling,
OFF
ON
fan runs all the time.
O
PERATION
WARNING
. T
O AVOID PERSONAL INJURY
,
DO NOT REMOVE ANY
. C
ONTACT A QUALIFIED
-U
TART
P
Cool/Heat
Switch
,

Advertisement

Table of Contents
loading