Optional wired-on SST plate (I1)

The 266 transmitter can be supplied with the optional "Wired
On Stainless Steel plate" (figure 4) which is permanently laser
printed with a custom text specified in phase of order. The
available space consists in 4 lines with 32 characters per line.
The plate will be connected to the transmitter with a Stainless
Steel wire.

Handling

The instrument does not require any special precautions during
handling although normal good practice should be observed.

Storage

The instrument does not require any special treatment if stored
as dispatched and within the specified ambient conditions.
There is no limit to the storage period, although the terms of
guarantee remain as agreed with the Company and as given in
the order acknowledgement.
ABB S.p.A.
Made in Italy
PRODUCT CODE
SEAL-H
SPEC.REQUEST
SENSOR DIAPH.-FILL
FLANGE/CONN.-GASKET/S
H DIAPH.-FILL
L DIAPH.-FILL
POWER SUPPLY
TS
MWP/OVP
LRL/URL
SPAN LIMITS
Calib.
Range
2600T
Tag
Number
PRESSURE TRANSMITTER
II 1/2 G Ex d IIC T6 - II 1/2 D Ex tD A21 IP67
T85°C FM09ATEX0023X - IECEx FME09.0002X
(-50°C<Ta<+75°C) POWER SUPPLY 42 Vdc/2W Max
II 1 G Ex ia IIC T6 - II 1/2 G Ex ia IIC T6 -
II 1 D Ex iaD 20 T85°C and II 1/2 D Ex iaD 21 T85°C
for electrical parameters see cert. FM09ATEX0024X
IP67 - IECEx FME09.0003X "FISCO Field Instrument"
II 3 G Ex nL IIC T6 - II 3 D Ex tD A22 IP67 T85°C
Ui = 42Vdc Ii < 25mA Ci < 13nF Li < 0,22mH
for electrical parameters see cert. FM09ATEX0025X
IECEx FME09.0004X "FNICO Field Instrument"
Figure 3: Product identification
SERIAL\NUMBER
SEAL-L
HW Rev.
MD:
PED:
OUTPUT SIGNAL
PS
Local keys below label
General Purpose IP67 Max.Supply Voltage 42 Vdc
XP (US) CL I/DIV1/GP ABCD, DIP CL II, III /DIV1/GP EFG,
FM
XP (Canada) CL I/DIV1/GP BCD, DIP CL II, III /DIV1/GP EFG,
US
C
APPROVED
CL I, ZONE 1, AEx/Ex d IIC T4 -50°C<Ta<+85°C
ENCL 4X T AMB=85°C "Seal not required" - "DUAL SEAL"
IS/Sec. Intrinseque (Entity) CL I, ZONE 0 AEx/Ex ia IIC T6,T5,T4
FM
CL I/DIV1/GP ABCD IS - CL II/DIV1/GP EFG - CLIII DIV1 when
US
C
APPROVED
conn. per dwg DH 3173 ENCL 4X "FISCO Field Instrument"-"DUAL SEAL"
CL I, ZONE 2 AEx nC IIC T6,T5,T4
FM
CL I, ZONE 2 Ex nL IIC T6,T5,T4
US
C
CL I/DIV2/GP ABCD NIFW when connected per drawing
APPROVED
DH 3173 ENCL 4X "FNICO Field Instrument" - "DUAL SEAL"
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD
Figure 4: 4-line layout of the optional wired-on Stainless Steel plate