Technical Data - Hilti TE 2-A Original Operating Instructions

Table of Contents

Advertisement

4. Technical data

Tool
Rated voltage
Weight as per EPTA-Procedure 01/2003
Dimensions (LxHxW)
Speed under no load
Speed
Hammering speed
Single impact energy
Chuck
Hammer drilling dia. range in concrete and masonry
Drilling using keyless chuck adaptor for cylindrical drill bits
- Drilling dia. range in wood
- Drilling dia. range in metal
Screwdriving using bit adaptor
- Wood screws
- HUD screws
Speed control
Forward / reverse
Gearing section sealed to prevent entry of dust and with permanent lubrication (maintenance-free)
-NOTE-
The vibration emission level given in this information sheet has been measured in accordance with a standardised
test given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assess-
ment of exposure. The declared vibration emission level represents the main applications of the tool. However if
the tool is used for different applications, with different accessories or poorly maintained, the vibration emission
may differ. This may significantly increase the exposure level over the total working period. An estimation of the
level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working
period. Identify additional safety measures to protect the operator from the effects of vibration such as: maintain
the tool and the accessories, keep the hands warm, organisation of work patterns.
Noise and vibration information (measured in accordance with EN 60745):
Typical A-weighted noise power level:
Typical A-weighted noise pressure level:
For the given sound power level as per EN 60745, the tolerance is 3 dB.
Wear ear protection!
Triaxial vibration value (vibration vector sum)
measured in accordance with EN 60745-2-1
measured in accordance with EN 60745-2-6
Uncertainty (K) for triaxial vibration value
Battery
Rated voltage
Battery capacity
Weight
Temperature monitoring
Type of cell
No. of cells
Right of technical changes reserved!
Printed: 07.07.2013 | Doc-Nr: PUB / 5137393 / 000 / 00
TE 2-A
24 V –––
- - -
3.9 kg
325 x 260 x 92 mm
980 r.p.m.
900 r.p.m.
0 ... 74 Hz (0 ... 4410 blows per min.)
1.5 joules
TE-C
4 to 16 mm
3 to 13 mm
3 to 10 mm
Up to 6 mm
Up to 6 mm
Electronic control switch
Electrical switch with interlock to prevent activation
when running
97 dB (A)
86 dB (A)
Drilling in metal, (a
)
h, D
Hammer drilling in concrete, (a
B24/2.0 NiCd
B24/2.4 NiCd
24 V –––
24 V –––
- - -
- - -
24 V × 2.0 Ah
24 V × 2.4 Ah
= 48 Wh
= 58 Wh
1.38 kg
1.45 kg
yes
yes
Nickel-cadmium Nickel-cadmium Nickel-metal hydride
SUB C type
SUB C type
20
20
2.5 m/s
2
)
14.5 m/s
2
h, HD
1.5 m/ s
2
B24/3.0 NiMH
24 V –––
- - -
24 V × 3.0 Ah
= 72 Wh
1.43 kg
yes
SUB C type
20
13
en

Advertisement

Table of Contents
loading

Table of Contents