Sensors Threshold

Table 3-1. Sensors Threshold
Sensor
Sensor
Number
Name
Fan
FCB
01h
FAN1
FCB
02h
FAN2
FCB
03h
FAN3
FCB
04h
FAN4
Voltage
14h
PS 12V
15h
PS 5V
Standby
16h
3.3V
17h
PS 3.3V
18h
PS 1.2V
The Converting Formula
Upper non-
Upper
recoverable
critical
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (RPM) = Raw_Data x 100
0xFF
0xFF
Actual_Reading (Volts) = Raw_Data x 0.062
0xD8
0xD4
Actual_Reading (Volts) = Raw_Data x 0.026
0xD7
0xD3
Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6
0xD3
Actual_Reading (Volts) = Raw_Data x 0.026
0xFF
0xFF
Actual_Reading (Volts) = Raw_Data x 0.0087
Upper
Lower non-
non-
recoverable
critical
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xCF
0xAB
0xCD
0xA9
0xCD
0xA9
0xFF
0x00
Sensors Threshold
3
Lower
Lower
critical
non-
critical
0x0F
0x00
0x0F
0x00
0x0F
0x00
0x0F
0x00
0xAF
0xB4
0xAE
0xB3
0xAD
0xB3
0x00
0x00
|