Appendix; Ssh/Telnet Enable And Disable - Dell PowerEdge C6145 Manual

Baseboard management controller
Hide thumbs Also See for PowerEdge C6145:
Table of Contents

Advertisement

Appendix

SSH/Telnet Enable and Disable

1
Reserved Extended Configuration (NetFn: 30H CMD:01H)
2
Set/Get Extended Configuration(NetFn: 30H CMD:03H/02H)
Configuration ID = 04h, Security
Attribute
ID
Service
1
Disabled
Example:
Get SSH/Telnet enable status:
1
Reserved Extended Configuration
ipmitool raw 0x30 0x01
Response: 0x01 (Reservation ID)
Size
Description
1
Disables or enables services. This
attribute takes precedence over the
individual feature enabled/disabled.
Once one service has been disabled, the
BMC must not allow users to enable the
corresponding feature and D5h
completion code must be returned. For
example, if HTTP/HTTPS is disabled,
user must not be able to enable the Web
Server through Web Server
Configuration (Configuration ID 0Ch).
In other words, Web can only be
disabled or enabled when
HTTP/HTTPS is enabled.
[0] - all services except IPMI are
disabled. This bit takes precedence over
other bits. Default is 0.
[1] - KVM/Virtual Storage, enabled by
default.
[2] - HTTP/HTTPS, enabled by default.
[3] - SSH/Telnet, disabled by default.
R/W
Appendix
|
71

Advertisement

Table of Contents
loading