This document is provided “as is“. The contents of this document are subject to change without any notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any...
Page 3
Documentation CD-ROM: The documentation of Ruijie Networks switches is stored in the CD-ROM package, which is provided to you together with the product you purchase. The CD-ROM is updated frequently, and may be more current than the printed documents.
Page 4
Ruijie Networks website, from which you can obtain the latest product documentation, causes and problems analysis of product faults, application solutions, and software upgrade. http://www.ruijie.com.cn/ Online customer services: Log in to Ruijie Networks website and click "Online Customer Services".
Product Overview The RG-S6200 series switches are the next-generation high-density full 10 G layer 3 IPv6 switches launched by Ruijie Networks. They are mainly applicable to the data center and positioned at the End of Row (EoR), as well as at the Top of Rack (ToR) to provide the convergence access for the servers and campus network with 10 G interfaces.
Product Appearance The front panel of the RG-S6200 series provides thirty-two 10 G ports, one console port, one 10/100/1000Base-T Ethernet port, and one USB2.0 port. The back panel provides two power slots and four fan slots. Figure 1-1 shows the appearance with the M6200-16XS extension module.
6. USB2.0 port extension module for the example) Back Panel The back panel of the RG-S6200 series provides the slots for the power supply modules and fan modules. Figure 1-3 Back panel of the RG-S6200 series with M6200-FAN-F and RG-M6200-AC650I-F modules...
Heat Dissipation The RG-S6200 series supports the heat dissipation scheme which combines the front-to-back air passage with power backward heat dissipation, thereby ensuring the device to function normally in the specified environment. Sufficient space (20 cm distance from both sides and the back plane of the cabinet) should be reserved to allow air circulation.
Page 9
Indicators Indicator Definition Description Status Indicates working Solid green The system has completed the initialization and is working status of the system normally. Blinking green The switch is being initialized with 3 HZ blinking frequency. Solid yellow The temperature (at the air intake and outlet) exceeds the normal operating temperature of the system.
Port link is not up. Modules The RG-S6200 series supports the following modules: M6200-16XS extension module for extending the RG-S6200 series . M6200_AC650I-F power supply module for 1+1 redundancy. M6200-FAN-F fan module for 3+1 redundancy. M6200-16XS Module Appearance M6200-16XS: Sixteen 10 G ports for extension modules and 16 SFP0+ ports.
Multiple extensible SFP+ cables of different lengths IEEE 802.3, SFF-8431/8432 and SFP MSA compliant Applicable Models M6200-16XS is applicable to the RG-S6200 series and other subsequent switches supporting this module, including: RG-S6200-48XS Indicator Description M6200-16XS comes with 16 SFP+ port indicators, which are defined as follows: 1F to 16F: Link/ACT indicator of SFP+ port.
Note: 1. Power supply status indicator 2. Power plug Features RG-M6200-AC650I-F provides the power supply with rated voltage of 12 V for the RG-S6200 series . The RG-M6200-AC650I-F power supply module has the following features: Supports the 1+1 redundancy.
Page 13
Supports the fan alarm function. Supports the hot swap of the fan tray. Applicable Models M6200-FAN-F is applicable for RG-S6200 series and other subsequent switches supporting this module, including: RG-S6200-48XS Indicator Description M6200-FAN-F comes with one fan status indicator, which is defined as follows: Status: Indicates the fan status indicators.
Preparation Before Installation Safety Suggestions To avoid personal injury and device damage, read carefully the safety suggestions before you install the RG-S6200 series. The following safety suggestions do not cover all possible dangers. Safety Precautions for Installing the System ...
Do not stare into any optical port under any circumstances, as this may cause permanent damage to your eyes. Installation Site Requirements The RG-S6200 series must be used indoors. To ensure the normal working and a prolonged durable life of the device, the installation site must meet the following requirements. Ventilation For the RG-S6200 series, you must ensure that sufficient space (10 cm distance from both sides and the back panel of the cabinet) is reserved at the ventilation openings to ensure the normal ventilation.
Page 16
Therefore, the ambient temperature and humidity of the RG-S6200 must meet the requirements listed in Table 2-1: Table 2-1 Temperature and humidity requirements of the RG-S6200 series Temperature Relative Humidity 0ºC–50ºC...
Page 17
System Grounding A good grounding system is the basis for the stable and reliable operation of the RG-S6200 series. It is the chief condition to prevent lightning stroke and resist interference. Please carefully check the grounding conditions on the installation site according to the grounding requirements, and perform grounding operations properly as required.
Lightning Resistance Considerations When the AC power cable is imported outdoors and directly connected to the power port of the switch, lightning line bank should be adopted to prevent the switch from being hit by lightning shocks. The lightning line bank can be fixed on the cabinet, work station, or the wall of the equipment room through line buckles and screws.
Table 2-4 List of installation tools Cross screwdriver, straight screwdriver, related electric Common tools and optical cables Bolts, diagonal pliers, straps Special-purpose tools Anti-static tool (anti-static glove) Meter Multimeter The RG-S6200 series are not provided with a tool kit. Please prepare tools on your own.
Product Installation Ensure that you have carefully read Chapter 2.Make sure that the requirements set forth in Chapter 2 have been met. Installation Process Confirmations Before Installation Before installation, confirm the following points: Whether sufficient airflow is available for the switch...
During the installation, fasten the pallet onto the rack and then place the front panel of the switch to the pallet. Fix the switch to the pallet and rack with screws. Because the depth and weight of the RG-S6200 series switch are 690 mm and 13.5 kg, the switch can be fastened with the pallet first, and then fastened onto the rack of the cabinet;...
Mounting the Switch to the Desktop In several cases, users do not have the 19-inch standard cabinets. In this case, the most frequent method is to mount the switch to a clean workstation. Step 1: Attach the four adhesive rubber pads provided in the carton onto the indentations on the four corners at the bottom of the switch.
Page 25
Step 3: Align the M6200-16XS to the guide rail of the extension port, and push it to the switch along the rail horizontally and slowly. When hearing “da”, which means the extension module, is inserted into the switch closely, fix the screws on the transition board.
Page 26
Insert the power module smoothly. Pay attention to the direction of the power panel to avoid the wrong insertion. If the position is not proper, you must withdraw the inserted module and then re-insert it. Removing the Power Module The process of removing the power module is reverse to the installation. Step 1: Wear the anti-static gloves.
Page 27
Step 2: Dismantle the blank panel of the fan supply, take the plane with the PCB in vertical view as the top plane, hold the end of the fan module with both hands, insert it to the chassis slowly along the guide rail until it is fully seated, and make sure that it is in good contact with the its slot, as shown in Figure 3-6.
Checking After Installation Before checking the installation, switch off the power supply to avoid personal injury or damage to the component due to connection errors. Check whether the ground line is connected. Check whether the cables and power input cables are correctly connected. ...
System Debugging Establishing Configuration Environment Establishing the Configuration Environment Connect the PC to the console port of the switch through the console cable, as shown in Figure 4-1. Figure 4-1 Schematic diagram of the configuration environment Connecting Console Cables Step 1: Connect one end of the DB-9 jack of the console cable to the serial port of the PC. Step 2: Connect one end of the console cable RJ45 to the console port of the switch.
Page 30
Choose Start > Programs > Accessories > Communications > Hyperterminal, the hyperterminal window is displayed, as shown in Figure 4-2. Figure 4-2 Click Cancel, a window is displayed as shown in Figure 4-3. Figure 4-3 In the Connectivity Note window, type the name of the new connetion, and then click OK. A window is displayed as shown in Figure 4-4.
Page 31
Figure 4-4 After selecting the serial port, click OK, the Serial Port Parameter Setting window is displayed as shown in Figure 4-5. Set the parameters as follows: baud rate 115200, data bit 8, parity check none, stop bit 1, and flow control as none. Figure 4-5 After setting the serial port parameters, click OK, the Hyperterminal window is displayed as shown in Figure 4-6.
Page 32
After initializing the system, adjust the terminal parameters. The parameters are as follows: baud rate 9600, data bit 8, parity check none, stop bit 1, and flow control as none. Figure 4-7 After adjusting the parameter, click OK, the Hyperterminal window is displayed as shown in Figure 4-7. Press Enter to enter the Configuration window.
Power-on Startup Checking Before Power-on The switch is fully grounded. The power cable is correctly connected. The power supply voltage complies with the requirement of the switch. The console cable is correctly connected; the terminal (can be a PC) used for configuration is already started; the parameters are already configured.
Troubleshooting General Troubleshooting Process Troubleshooting Common Faults Symptom Possible Causes Solution Please contact Ruijie Networks Forgetting the login password of the Customer Service Department for management page technical support. Check whether the power socket at The power supply module does not...
Page 35
Symptom Possible Causes Solution damaged. At this time, the switch already stops the normal service exchanges. Check in time the working environment of the switch, clean the dust on the cabinet and reinforce the refrigeration effect. The FAN indicator on the front panel The number of fan inserted is less Check the fan number inserted.
Appendix A: Connectors and Connection Media 1000BASE-T/100BASE-TX/10BASE-T Ports The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category-5 UTP or STP, which can be up to 100 m.
SFP+ Copper Cable Connection For the SFP+ port, the SFP+ copper cable of Ruijie Networks can be used. Each end of the cable is connected to a 10 G module which can be directly connnected with the port supporting the SFP+ copper cable...
Appendix B Mini-GBIC Modules and Technical Specifications Ruijie Networks provides appropriate 1000M SFP modules (Mini-GBIC modules) according to the types of interfaces of the switch modules. You can select the SFP module to suit your specific needs. The following models and technical specifications of some 1000M SFP modules are listed for your reference.
Appendix C SFP+ Modules and Technical Specifications Ruijie Networks provides appropriate 10 G SFP+ modules according to the types of interfaces of the switch modules. You can select the SFP+ module to suit your specific needs. The following models and technical specifications of some 10 G SFP+ modules are listed for your reference.
Appendix D SFP+ Copper Cables and Technical Specifications Ruijie Nerworks provides appropriate SFP+ copper cables according to the types of interfaces of the switch modules. You can select the SFP+ copper cable to suit your specific needs. The models and technical specifications of some SFP+ copper cables are listed below for your reference.