LEGRAND CX-100 Installation Instructions Manual

LEGRAND CX-100 Installation Instructions Manual

Wattstopper pir occupancy sensor with light level and isolated relay
Table of Contents
  • Instructions en Français
  • Description de L'appareil
  • Caractéristiques
  • Instructions de Câblage
  • Réglage du Détecteur
  • Dépannage
  • Informations Pour Commander
  • Instrucciones en Español
  • Descripción de la Unidad
  • Especificaciones
  • Instalación
  • Instrucciones de Cableado
  • Ajuste del Sensor
  • Solución de Problemas
  • Información para Pedidos
  • Warranty Information
  • Información de la Garantía

Advertisement

Available languages

Available languages

No: 24227 – 11/16 rev. 1
Catalog Number • Numéro de Catalogue • Número de Catálogo: CX-100
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
CX-100-U is BAA and TAA compliant (Product produced in the U.S.)
The CX-100 is a 24VDC passive infrared (PIR) occupancy sensor which controls lighting and HVAC systems based on occupancy. It
also has a light level feature that can be used to keep sections of lights from turning on if the ambient light level is sufficient. The CX-100
contains an isolated relay with Normally Open and Normally Closed outputs for interfacing with HVAC or EMS.
PIR sensing systems are passive systems which react to changes in infrared energy (moving body heat) within the coverage area. PIR
sensors must directly "see" motion of an occupant to detect them, so careful consideration must be given to sensor placement.
Coverages shown are maximum and represent coverage for walking motion. Actual coverage will vary slightly depending on mounting
height and furnishings.
Masking the lens: Opaque adhesive tape is supplied so that sections of the sensor's lens can be masked. This restricts the sensor's
view and allows you to eliminate coverage in unwanted areas.
Dense Wide Angle Lens (Standard)
up to 2000 sq ft for walking motion
up to 1000 sq ft for desktop motion
Two-Sided Aisleway Lens (-3)
up to 134 linear ft for walking motion
Wattstopper
PIR Occupancy Sensor with Light Level and Isolated Relay
Détecteur de Mouvement IRP avec contrôle du niveau de luminosité
et relais isolé
Sensor de Ocupación PIR con nivel de luz y relé aislado
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
UNIT DESCRIPTION
COVERAGE PATTERNS
®
SPECIFICATIONS
Voltage ................................................................. 24VDC
Current Consumption ............................................. 19mA*
Power Supply ............................ Wattstopper Power Pack
Isolated Relay Rating .................................... 1A@24VDC
Time Adjustment ........................ 15 seconds—30 minutes
Sensitivity Adjustment ..................... Minimum—Maximum
Light Level Adjustment ..................................... 3—200FC
*Current consumption can be slightly higher when only one
sensor per power pack is used.
Long Range Lens (-1)
up to 90 linear ft for walking motion
One-Sided Aisleway Lens (-4)
up to 50 linear ft for walking motion

Advertisement

Table of Contents
loading

Summary of Contents for LEGRAND CX-100

  • Page 1 The CX-100 is a 24VDC passive infrared (PIR) occupancy sensor which controls lighting and HVAC systems based on occupancy. It also has a light level feature that can be used to keep sections of lights from turning on if the ambient light level is sufficient. The CX-100 contains an isolated relay with Normally Open and Normally Closed outputs for interfacing with HVAC or EMS.
  • Page 2: Installation

    Swivel Bracket Fig. C Industrial Mount Bracket MB-1 In an industrial setting, the MB-1 can be used to mount the CX-100-3 or CX-100-4 to a variety of structures or fixtures, including fluorescent fixtures. MB-1 The MB-1 features an L-shaped bracket and sensor housing. The housing can be positioned so that the sensor’s view is straight down (CX-100-3), or directioned down an aisle (CX-100-4).
  • Page 3: Wiring Directions

    WARNING: TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING. Each Wattstopper BZ series power pack can supply power for up to 6 CX-100 sensors. When using more sensors than this, multiple power packs are required. FIRST–connect the low voltage: •...
  • Page 4: Troubleshooting

    • If the lights do not turn off, replace power pack. Reconnect blue wire. Catalog# Description • If the lights turn off, the problem may be in the sensor–to check: CX-100 Occupancy Sensor, Dense Wide Angle Lens (Std) 4. Reconnect the blue wire. CX-100-1 Occupancy Sensor, Long Range Lens 5.
  • Page 5: Instructions En Français

    INSTALLATION Fig. A Les détecteurs CX-100 peuvent être montés sur des murs ou plafonds avec le support pivotant fourni, ainsi que le couvercle de boîte de jonction fourni si nécessaire (voir figure C). Il est plus efficace de monter le détecteur à la hauteur du luminaire. Les détecteurs -3 et -4 peuvent également être montés sur des luminaires industriels à...
  • Page 6: Instructions De Câblage

    Fig. C Support pivotant Support de montage industriel MB-1 Dans une application industrielle, le MB-1 peut être utilisé pour monter le CX-100-3 ou le MB-1 CX-100-4 sur différents luminaires ou structures, y compris les luminaires fluorescents. Le MB-1 comprend un support en forme de L et un boîtier de détecteur. Le boîtier peut être positionné...
  • Page 7: Réglage Du Détecteur

    Câblage D'UNE CHARGE D'ÉCLAIRAGE CONTRÔLÉE PAR LA PRÉSENCE ET D'UNE SECONDE CHARGE CONTRÔLÉE PAR LA PRÉSENCE ET LE NIVEAU DE LUMINOSITÉ (ÉCLAIRAGE AMBIANT) – raccordez: • le fil BLEU du bloc d'alimentation au fil JAUNE du capteur. Plusieurs détecteurs et systèmes d'éclairage •...
  • Page 8: Dépannage

    Numéro de Description Causes possibles catalogue 1. Emplacement du détecteur ou ajustement CX-100 Détecteur de présence, lentille grand-angle dense (std) de l'angle inapproprié qui provoque des CX-100-1 Détecteur de présence, lentille longue portée détections hors de la zone de portée souhaitée.
  • Page 9: Instrucciones En Español

    INSTALACIÓN Los sensores CX-100 pueden montarse a la pared o al cielo raso con el soporte giratorio Fig. A suministrado, y con la placa de la cubierta de la caja de conexiones suministrada, si es necesario (consulte la figura C).
  • Page 10: Instrucciones De Cableado

    Fig. C Soporte giratorio Soporte de montaje industrial MB-1 En un entorno industrial, el MB-1 se puede utilizar para montar el CX-100-3 o CX-100-4 a una variedad de estructuras o accesorios, incluidas lámparas fluorescentes. MB-1 El MB-1 cuenta con un soporte en forma de L y una...
  • Page 11: Ajuste Del Sensor

    Cableado DE UNA SOLA CARGA DE ILUMINACIÓN PARA CONTROL DE OCUPACIÓN, Y UNA SEGUNDA CARGA PARA CONTROL DE OCUPACIÓN Y NIVEL DE LUZ (LUZ AMBIENTE-conectar: • Cable AZUL desde la fuente de alimentación al cable AMARILLO del sensor. • Cable AZUL desde la fuente esclavo al cable AZUL del sensor. •...
  • Page 12: Información Para Pedidos

    No. 24227 – 11/16 rev. 1 © Copyright 2016 Legrand All Rights Reserved. 800.879.8585 © Copyright 2016 Tous droits réservés Legrand. www.legrand.us/wattstopper © Copyright 2016 Legrand Todos los derechos reservados.

Table of Contents