TROUBLESHOOTING GUIDE
Problem
Seasonal Adjust seems high
Solar Sync still sending Seasonal Adjust
when Controller Bypass switch is in the
"Bypass" position
32
Causes
• Region too low
• Water Adjustment setting too high
Solar Sync's automated Seasonal
Adjustment cannot be deactivated by
the Bypass switch. The Bypass switch
only controls the Rain/Freeze shutoff
function of the Solar Sync.
Solutions
Decrease the value of the Water Adjustment setting.
If you minimize the Water Adjustment scale at 1 and
still require reduced seasonal adjustment, move up one
Region (from 2 to 3, for example) and start at Water
Adjustment setting 5. Solar Sync will immediately update
the Seasonal Adjust on the Controller. If it is still too high,
repeat the adjustment until the desired seasonal adjust is
showing on the controller.