Operation; Operation Range - Daikin FDXM25F3V1B Operation Manual

Hide thumbs Also See for FDXM25F3V1B:
Table of Contents

Advertisement

d
e
f
a
g
c
a
Indoor unit
b
Outdoor unit
c
User interface
d
Air inlet
e
Air outlet
f
Refrigerant piping and electric wiring
g
Drain pipe
h
Earth wire to ground outdoor unit to prevent electric
shocks.
CAUTION
Do not insert fingers, rods or other objects into the air inlet
or outlet. Do not remove the fan guard. When the fan is
rotating at high speed, it will cause injury.
CAUTION
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch and appliance problems may happen.
For checking and adjusting the internal parts, contact your
dealer.
NOTICE
Do not wipe the controller operation panel with benzine,
thinner, chemical dust cloth, etc. The panel may get
discoloured or the coating peeled off. If it is heavily dirty,
soak a cloth in water-diluted neutral detergent, squeeze it
well and wipe the panel clean. Wipe it with another dry
cloth.
NOTICE
Never press the button of the user interface with a hard,
pointed object. The user interface may be damaged.
NOTICE
Never pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.
FDXM25~60F3V1B
Split system air conditioners
4P456959-1 – 2017.03
b
h
3

Operation

3.1

Operation range

For combination with R410A outdoor unit, refer to the following table:
Outdoor units
RR71~125
Outdoor
temperature
Indoor
temperature
RQ71~125
Outdoor
temperature
Indoor
temperature
RXS25~60
Outdoor
temperature
Indoor
temperature
2MXS50
Outdoor
temperature
Indoor
temperature
3MXS40~68
Outdoor
temperature
4MXS68~80
Indoor
5MXS90
temperature
RZQG71~140
Outdoor
temperature
Indoor
temperature
RZQSG71~140 Outdoor
temperature
Indoor
temperature
RZQ200~250
Outdoor
temperature
Indoor
temperature
For combination with R32 outdoor unit, refer to the following table:
Outdoor units
2MXM50
Outdoor
temperature
3MXM40~68
Indoor
4MXM68~80
temperature
5MXM90
RXM25~60
Outdoor
temperature
Indoor
temperature
RZAG71~140
Outdoor
temperature
Indoor
temperature
3 Operation
Cooling
Heating
–15~46°C DB
18~37°C DB
12~28°C WB
–5~46°C DB
–9~21°C DB
–10~15°C WB
18~37°C DB
10~27°C DB
12~28°C WB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–15~50°C DB
–19~21°C DB
–20~15.5°C WB
18~37°C DB
10~27°C DB
12~28°C WB
–15~46°C DB
–14~21°C DB
–15~15.5°C WB
20~37°C DB
10~27°C DB
14~28°C WB
–5~46°C DB
–14~21°C DB
–15~15°C WB
20~37°C DB
10~27°C DB
14~28°C WB
Cooling
Heating
–10~46°C DB
–15~24°C DB
–16~18°C WB
–18~32°C DB
10~30°C DB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–20~52°C DB
–19.5~21°C DB
–20~15.5°C WB
18~37°C DB
10~27°C DB
12~28°C WB
Operation manual