Error Condition
The disk array responds "Not
Ready" or the disk array has
displayed "Not Ready" and
timed out.
The host does not boot up.
The HBA is not configured
by the host on bootup.
Storage is not seen on the
adapter by the console
program before boot, or on
the host after boot.
Troubleshooting
Recommended Action
Contact HP.
Check the HBA and make sure it was installed properly according to
the HBA manufacturer's instructions.
Check the HBA topology. It should be set to fabric.
Verify that the HBA is supported by the version of the host operating
system and the required minimum ECO kits are installed. ECO kits
for HP products are available online from http://www.itrc.hp.com.
Check the HBA and make sure it was installed properly.
Verify that the topology is set correctly for the HBA and that the Fibre
Channel cables are properly connected. Check the status information
LEDs for the HBA, the status LEDs, and other information Fibre
Channel switch and the XP array.
Check the zoning on the switch.
Verify that the disk array Host Mode is set correctly. The Host Mode
setting for Open VMS is 05.