Error Conditions - HP StorageWorks XP48 Configuration Manual

Hide thumbs Also See for StorageWorks XP48:
Table of Contents

Advertisement

Error conditions

Error Condition
The logical devices are not
recognized by the host.
Physical volumes cannot be
created.
Logical volumes cannot be
created.
34
Depending on your system configuration, you may be able to view error
messages as follows:
• View SIMs in Command View (Device Health tab).
• View R-SIMs in Remote Control XP, including reference codes and
severity levels of recent R-SIMs.
• View SIMs that generate SNMP traps on the host.
Recommended Action
Verify that the host mode is set correctly for the XP array. See "Setting
the Host Mode for the disk array ports"
Verify that the CU is between 0<>31, AND LDEV is between
0<>255.
Verify that the READY indicator lights on the disk array are ON.
Verify that the topology is set correctly for the HBA and that the Fibre
Channel cables are properly connected. Check the status information
LEDs for the HBA, the status LEDs, and other information Fibre
Channel switch and the XP array.
Check zoning on the switch.
Verify that the disk array logical devices are correctly formatted. See
"Configure disk array devices"
Verify that the volume capacity for OPEN-x volumes is not greater
than the maximum capacity allowed. See the Device Emulations
Appendix.
Verify that the capacity of the volume group is not less than the total
capacity of the partitioned logical volume.
HP StorageWorks Disk Array XP Operating System Configuration Guide: OpenVMS
(page
23).
(page
30).

Advertisement

Table of Contents