Kenwood TK-3202 Service Manual page 26

Uhf fm transceiver
Hide thumbs Also See for TK-3202:
Table of Contents

Advertisement

Item
Condition
7. DQT
1) Test CH: Center, Low, High
balance
(3 points)
adjustment
Deviation meter filter
• Wide 5k
LPF: 3kHz
HPF: OFF
PTT: ON
• Wide 4k
2) Test CH: Center
PTT: ON
• Narrow
3) Test CH: Center
PTT: ON
8. QT deviation 1) Test CH: Center, Low, High
adjustment
(3 points)
• Wide 5k
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
• Wide 4k
2) Test CH: Center
PTT: ON
• Narrow
3) Test CH: Center
PTT: ON
9. DQT
1) Test CH: Center, Low, High
deviation
(3 points)
adjustment
Deviation meter filter
• Wide 5k
LPF: 3kHz
HPF: OFF
PTT: ON
• Wide 4k
2) Test CH: Center
PTT: ON
• Narrow
3) Test CH: Center
PTT: ON
Receiver Section
Item
Condition
1. BPF wave
1) Center frequency
adjustment
Spectrum analyzer setting
Center f.: 455.10MHz
E
Span: 100MHz
RBW: 100kHz
VBW: 30kHz
ATT: 10dB
2) High-edge frequency
Spectrum analyzer setting
Center f.: 469.90MHz
Span: 120MHz
3) Low-edge frequency
Spectrum analyzer setting
Center f.: 440.05MHz
Span: 80MHz
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
PC
Deviation
SP/MIC
meter
connector
Oscilloscope
AG
AF VTVM
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Panel
ANT
PC
Spectrum TX-RX BPF
analyzer
TK-3202
Adjustment
Parts
Method
KPG-87D Make the demodu-
(M2)
lation wave into
square waves
± 40Hz
0.85kHz
± 40Hz
0.70kHz
± 40Hz
0.45kHz
± 40Hz
0.75kHz
± 40Hz
0.60kHz
± 40Hz
0.35kHz
Adjustment
Parts
Method
KPG-87D Adjust the wave-
(M2)
form as shown to
the Fig. 1 (page 27)
Specifications/Remarks
Specifications/Remarks
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents