Cisco Nexus 9000 Series Troubleshooting Manual page 88

Nx-os release 7.x
Hide thumbs Also See for Nexus 9000 Series:
Table of Contents

Advertisement

POAP Fails
2013 Oct 29 22:25:10 switch %$ VDC-1 %$ %POAP-2-POAP_FAILURE: POAP DHCP discover phase
failed
2013 Oct 29 22:25:12 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Abort Power On Auto
Provisioning and continue with normal setup ?(yes/no)[n]:
2013 Oct 29 22:25:46 switch %$ VDC-1 %$ %POAP-2-POAP_DHCP_DISCOVER_START: POAP DHCP
Discover phase started
2013 Oct 29 22:25:46 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Abort Power On Auto
Provisioning and continue with normal setup ?(yes/no)[n]:
Abort Auto Provisioning and continue with normal setup ?(yes/no)[n]: yes
• Check the failure reason in the log files. Two POAP log files are saved on the bootflash. Logs from the
POAP process are stored in the file that ends with poap_pid_init.log as shown below. The failure reason
should appear toward the end of this file.
bash-4.2# tail 20131029_222312_poap_5367_init.log -n 3
Tue Oct 29 22:27:41 2013:poap_net_rx_pkt: Droppping the pakcet due to Ethernet hdrparsing
error on if_index - 5000000
Tue Oct 29 22:27:41 2013:DEST IP is not Broadcast
Tue Oct 29 22:27:41 2013:poap_net_rx_pkt: Droppping the pakcet due to Ethernet hdrparsing
error on if_index - 5000000
• Check to see if the POAP script file that is downloaded from your DHCP or TFTP server fails in the
process of running. Depending on the stage of the failure, the device might proceed with the normal
setup or reboot.
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Assigned IP address:
172.23.40.181
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Netmask: 255.255.255.0
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: DNS Server: 172.21.157.5
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Default Gateway: 172.23.40.1
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Script Server: 172.23.40.6
2013 Oct 29 22:42:34 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Script Name: poap.py
2013 Oct 29 22:42:45 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: The POAP Script download
has started
2013 Oct 29 22:42:45 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: The POAP Script is being
downloaded from [copy tftp://172.23.40.6/poap.py bootflash:scripts/script.sh vrf
management ]
2013 Oct 29 22:42:46 switch %$ VDC-1 %$ %POAP-2-POAP_SCRIPT_DOWNLOADED: Successfully
downloaded POAP script file
2013 Oct 29 22:42:46 switch %$ VDC-1 %$ %POAP-2-POAP_INFO: Script file size 21965, MD5
checksum 1bd4b86892439c5785a20a3e3ac2b0de
2013 Oct 29 22:42:46 switch %$ VDC-1 %$ %POAP-2-POAP_SCRIPT_STARTED_MD5_NOT_VALIDATED:
POAP script execution started(MD5 not validated)
2013 Oct 29 22:47:57 switch %$ VDC-1 %$ %POAP-2-POAP_FAILURE: POAP script execution
aborted
• The POAP script file logs are written to a file under the bootflash scheme. The filename starts with
poap.log. If there are multiple file logs, look at the one with the most recent time stamp for any errors.
bash-4.2# tail poap.log.22_42_46
CLI : show file volatile:poap.cfg.md5.poap_md5 | grep -v '^#' | head lines 1 | sed 's/
.*$//'
INFO: md5sum 46684d8f8b7c5ffac3b37ac8560928e5 (.md5 file)
CLI : show file volatile:poap.cfg md5sum
INFO: md5sum 46684d8f8b7c5ffac3b37ac8560928e5 (recalculated)
CLI : config terminal ; boot nxos bootflash:poap/system.img
CLI : copy running-config startup-config
CLI : copy volatile:poap.cfg scheduled-config