Remove the hairs from the cutters and guards
with the brush supplied.
Do not clean more than one cutter and guard at
a time, since they are all matching sets. If you
accidentally mix up the cutters and guards, it may
take several weeks before optimal shaving
performance is restored.
Put the shaving heads back into the shaving
unit. Put the retaining frame back into the
shaving unit, press the wheel and turn it
clockwise.
Cause 3: the shaving heads are damaged or worn.
B
Remove the retaining frame.
Remove the old shaving heads from the
shaving unit and replace them with new ones.
Damaged or worn shaving heads (cutters and
guards) may only be replaced with original HQ6
Philishave Quadra shaving heads.
Put the retaining frame back into the shaving
unit, press the wheel and turn it clockwise.
2
The shaving unit has come off the shaver.
C
If the shaving unit becomes detached from the
shaver, check whether the hinge spring is still
properly attached, i.e. has not come loose and
does not show any cracks or damage. If the
hinge spring is still properly attached, the
shaving unit can be easily put back on the
shaver again. However, if the hinge spring has