GE G60 UR Series Instruction Manual page 519

Generator protection system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 30 of 58)
ADDR
REGISTER NAME
83F1
EGD Slow Producer Exchange 1 Configuration Time
83F3
EGD Slow Producer Exchange 1 Size
83F4
...Repeated for module number 2
EGD Fast Production (Read/Write Setting)
8400
EGD Fast Producer Exchange 1 Function
8401
EGD Fast Producer Exchange 1 Destination
8403
EGD Fast Producer Exchange 1 Data Rate
8404
EGD Fast Producer Exchange 1 Data Item 1 (20 items)
8418
Reserved (80 items)
EGD Slow Production (Read/Write Setting) (2 modules)
8500
EGD Slow Producer Exchange 1 Function
8501
EGD Fast Producer Exchange 1 Destination
8503
EGD Slow Producer Exchange 1 Data Rate
8504
EGD Slow Producer Exchange 1 Data Item 1 (50 items)
8536
Reserved (50 items)
8568
...Repeated for EGD Exchange 2
Remote RTD inputs (Read/Write Grouped Setting) (12 modules)
86D0
Remote RTD 1 Function
86D1
Remote RTD 1 ID
86D7
Remote RTD 1 Type
86D8
Remote RTD 1 Application
86D9
Remote RTD 1 Alarm Temperature
86DA
Remote RTD 1 Alarm Pickup Delay
86DB
Remote RTD 1 Trip Temperature
86DC
Remote RTD 1 Trip Pickup Delay
86DD
Remote RTD 1 Trip Reset Delay
86DE
Remote RTD 1 Trip Voting
86DF
Remote RTD 1 Block
86E0
Remote RTD 1 Open
86E1
Remote RTD 1 Target
86E2
Remote RTD 1 Events
86E3
Repeatead for remote RTD input 2
86F6
Repeatead for remote RTD input 3
8709
Repeatead for remote RTD input 4
871C
Repeatead for remote RTD input 5
872F
Repeatead for remote RTD input 6
8742
Repeatead for remote RTD input 7
8755
Repeatead for remote RTD input 8
8768
Repeatead for remote RTD input 9
877B
Repeatead for remote RTD input 10
878E
Repeatead for remote RTD input 11
87A1
Repeatead for remote RTD input 12
Remote RTD inputs (Read Only Actual Values)
87C0
Remote RTD 1 Value
87C1
Remote RTD 2 Value
87C2
Remote RTD 3 Value
87C3
Remote RTD 4 Value
87C4
Remote RTD 5 Value
87C5
Remote RTD 6 Value
87C6
Remote RTD 7 Value
87C7
Remote RTD 8 Value
87C8
Remote RTD 9 Value
87C9
Remote RTD 10 Value
87CA
Remote RTD 11 Value
GE Multilin
RANGE
0 to 4294967295
0 to 65535
0 to 1
0 to 4294967295
50 to 1000
0 to 65535
---
0 to 1
0 to 4294967295
500 to 1000
0 to 65535
---
0 to 1
---
0 to 3
0 to 5
1 to 200
5 to 600
1 to 200
5 to 600
5 to 600
0 to 13
0 to 65535
0 to 2
0 to 2
0 to 1
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
G60 Generator Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F003
---
1
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
---
F205
---
1
F174
0 (100 ohm Platinum)
---
1
F550
°C
1
F001
seconds
5
F001
°C
1
F001
seconds
5
F001
seconds
5
F001
---
1
F603
---
1
F300
---
1
F552
---
1
F109
---
1
F102
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
DEFAULT
0
0
0 (Disabled)
B
0
1000
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
"RRTD 1"
0 (None)
130
5
130
5
5
0 (None)
0
0 (None)
0 (Self-Reset)
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
B-37