Each system requires a different parametrisation. Follow the procedure for accessing the
two menus, given below; for the parameters to be modified, refer to the tables given
alongside the plumbing diagrams.
Press the Reset button for 10 seconds to access the card Service Menu.
Press the Heating buttons to select "tS", "In", "Hi" or "rE". tS" means Transparent Param-
eters Menu, "In" Information Menu, "Hi" History Menu, and "rE" History Menu Reset. Se-
lect "tS" and press the RESET button.
The card has 29 transparent parameters also modifiable from Remote Control (Service
Menu).
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 sec-
onds to exit to the card Service Menu.
Press the Summer/Winter button for 10 seconds to access the card System Type Menu.
The card has 21 transparent parameters.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to modify the value of a parameter: the change will be au-
tomatically saved.
Press the Summer/Winter button for 10 seconds to exit the card System Type Menu.
Check/Change parameter P02 of the "Transparent Parameters Menu" to .
Change parameter P.02 of the "System Type Menu" to 1.
Change parameter P.09 of the "System Type Menu" to 1.
138
Check/Change parameter P02 of the "Transparent Parameters Menu" to .
Change parameter P.02 of the "System Type Menu" to 1.
Change parameter P.09 of the "System Type Menu" to 1.
138
72/139
I
298
306
D
A
72/139
42
I
130
298
306
D
B
cod. 3540S736 - Rev. 00 - 09/2013
Check/Change parameter P02 of the "Transparent Parameters Menu" to .
Change parameter P.02 of the "System Type Menu" to 1.
Change parameter P.09 of the "System Type Menu" to 1.
Change parameter P.11 of the "System Type Menu" to 1.
138
Check/Change parameter P02 of the "Transparent Parameters Menu" to .
Change parameter P.01 of the "System Type Menu" to 4.
Change parameter P.02 of the "System Type Menu" to 1.
Change parameter P.09 of the "System Type Menu" to 1.
138
Check/Change parameter P02 of the "Transparent Parameters Menu" to .
Change parameter P.02 of the "System Type Menu" to 1.
Change parameter P.09 of the "System Type Menu" to 1.
For the electrical connection and the zone system settings, refer to the "FZ4 zone regu-
lator" handbook
138
42
I
298
95
306
D
72/139
I
307
298
D
FZ4
72/139
72/139
Zona 1
Zona 2
TS
TS
I
PZ
PZ
SM
SM
M