Trotec TTK 54 E Operating Manual
Hide thumbs Also See for TTK 54 E:

Advertisement

TTK 54 E / TTK 66 E
EN
OPERATING MANUAL
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TTK 54 E

  • Page 1 TTK 54 E / TTK 66 E OPERATING MANUAL DEHUMIDIFIER...
  • Page 2: Table Of Contents

    Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 3: Safety

    • Insert the mains plug into a properly secured mains socket. • Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 4 People who use this device must: • be aware of the dangers that occur when working with electric devices in damp areas. • have read and understood the operating manual, especially the Safety chapter. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 5: Information About The Device

    Designation Control panel Transport handle Wheels Air inlet with air filter Power cable holder Condensation drain hose Condensation drain hose connection Condensation tank with filling level indicator Air outlet Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 6: Transport And Storage

    • with a cover to protect it from invasive dust if necessary • Place no further devices or objects on top of the device to prevent it from being damaged. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 7: Operation

    • Ensure that the float inside the condensation tank is inserted correctly. • Ensure that the condensation tank is empty and inserted correctly. Connecting the power cable • Insert the mains plug into a properly secured mains socket. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 8 An acoustic signal is emitted each time a setting is ð Continuous operation is selected. activated. Info For continuous operation the condensation drain hose can be connected in order to continuously drain the accumulating condensate. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 9 When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data. The device dehumidifies the air constantly and regardless of the relative room humidity. The fan runs at the highest speed. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 10 Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 11: Errors And Faults

    Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec. • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 12: Error Codes

    The indication will disappear the moment the automatic defrost process is completed. Condensation tank full or Empty the condensation tank or not inserted correctly check the condensation tank for correct fit. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 13: Maintenance

    12. Date: ......Signature: ......Signature: ......Signature: ......Signature: ......13. Date: ......14. Date: ......15. Date: ......16. Date: ......Signature: ......Signature: ......Signature: ......Signature: ......Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 14 3. Allow the filter to dry completely. Do not insert a wet filter repaired by specialist companies for cooling and air- into the device! conditioning or by Trotec. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 15 • Reconnect the device to the mains. If you do not intend to use the device for a considerable time: • Store the device according to the Storage chapter. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 16: Technical Annex

    SENSOR SWITCH TEMP. BLUE BLUE BLACK BLUE COMP. (or CN4) (or CN6A /CN6B/CN6C) PTC. OverLoad STARTER Protector M AIN BOARD WHITE(or BLUE) Y/G(or GREEN) POW ER 202026490419 BLACK(or BROWN) Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 17 Volute shell subassembly Capacitor Rear Panel assembly 3.1.1 Volute shell subassembly Chassis Assembly Air inlet grille 3.1.2 Centrifugal Fan Chassis Subassembly Drain Stopper 3.1.3 Single phase asynchronous motor Universal wheel Ionizer Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 18 Air inlet grille Volute shell subassembly Chassis Assembly Drain Stopper 3.1.1 Volute shell subassembly Chassis Subassembly Ionizer 3.1.2 Centrifugal Fan Universal wheel 3.1.3 Single phase asynchronous motor Power Supply Cable Subassembly Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 19: Disposal

    Further information is provided on the nameplate. Dispose of the refrigerant appropriately and according to the national regulations. Operating manual – dehumidifier TTK 54 E / TTK 66 E...
  • Page 20 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...