5 Service Fixture & Tools
5.1.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-PAVC" web-site in
"TSN system", together with Maintenance software.
5.2.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
VFK1364
2
VFK1461
3
VFK1388
4
VFK1716
5
VFK1461
6
VFK1461
7
VFK1870
Table S1 Extension Cable List
Connection
FP31 (MAIN) - CCD UNIT
FP71 (MAIN) - LENS UNIT
FP6102 (MAIN) - FP4802 (FRONT)
FP6103 (MAIN) - FP8101 (MONITOR)
FP6105 (MAIN) - BATTERY CHATCER UNIT
FP61 (MAIN) - OPERATION FPC UNIT
PS6101 (MAIN) - FP6001 (JACK)
11
Form
14PIN 0.5 FFC
20PIN 0.5 FFC
12PIN 0.5 FFC
25PIN 0.3 FFC
20PIN 0.5 FFC
20PIN 0.5 FFC
20PIN B to B