7.0 Storing Your Carpet Extractor

Store your carpet extractor in temperatures over 40 degrees Fahrenheit. To prevent
moisture from damaging the vacuum motor during storage, empty the recovery tank and
store with the lid open. Store in an upright position in a dry area.
If you plan on storing your extractor in freezing conditions or for a long period of time,
you must winterize your carpet extractor to protect the pump from freezing or damage
being caused to fittings and valves. Damage due to freezing is NOT covered under
the warranty. The following procedure should help prevent your carpet extractor from
freezing and prevent pump and seals from drying out.
Recommended Procedure for Storage
• Pour a quart of RV Water System Antifreeze into the solution tank.
• Connect the solution hose to the front of the machine.
• Use the wand to spray the mixture into a bucket.
• Vacuum the excess mixture out of the solution tank and into the recovery tank.
Dispose of the antifreeze properly.
To return to service, flush the pressure system by repeating the above steps, using
fresh water in place of antifreeze.
(12) PE500 12-Gallon, 500 PSI Carpet Extractor
5.0 Maintenance Continued
5.2
Rinse Out Recovery
Buildup of fine silt and debris can damage the auto-dump pump and dump valve.
Cleaning out the recovery tank on a regular basis will extend the life of these
components, as well as keep the tank and machine smelling better. To rinse out recovery
tank, remove the recovery tank lid and open the dump valve. Place a bucket under the
dump valve. Use a hose to rinse the dirt and debris out of the recovery tank. Close the
dump valve and spray the tank with deodorizer or disinfectant. Proceed to waste pump
cleaning and replace the recovery tank lid. Dispose of dirty water and debris.
5.3
Clean Pump Inlet Filter
CAUTION: Before proceeding with this procedure, make sure both the power cords are
disconnected.
• To examine the filter, open the solution tank lid on the front of the machine. The filter
is in the bottom of the solution tank.
• Grasp the filter cap and unscrew the filter from the brass nipple by turning counter-
clockwise. Clean the filter by rinsing with fresh water. If necessary, use a toothbrush
to remove detergent buildup. Replace as needed.
NOTE: Heavy buildup is a warning sign that the solution system should be flushed.