Do NOT
Transporting
the Unit
2.5 Siting and Safety Notes
Siting the
The unit must only be installed indoors – the unit is not
Unit
designed for, or suitable for installation outside. The Unit
needs to be sited where the ambient temperature never
goes below 5 degrees. If the unit is to be left unused for any
significant period of time during which the ambient
temperature could cause the unit or pipe work from the unit
to freeze, it should be drained down.
Shut off the
When cleaning the unit, shut off the power supply.
power
You MUST
You must use a suitable power supply that is appropriately
fused.
2.6 General Requirements
IMPORTANT: PLEASE READ AND ENSURE THAT YOU UNDERSTAND
THESE INSTRUCTIONS BEFORE INSTALLING THE ESP Ecocent ("DHW
ASHP" or "unit"). INCORRECT INSTALLATION WILL INVALIDATE ANY
GUARANTEE.
PLEASE NOTE THAT THERE ARE ESSENTIALLY 2 UNITS COMBINED INTO
ONE IN THE ESP ECOCENT AND YOU MUST BE SURE TO
UNDERSTAND BOTH ELEMENTS - THE INDIRECT HOT WATER
CYLINDER AND THE AIR SOURCE HEAT PUMP. PLEASE ALSO NOTE THE
ECOCENT CAN BE INSTALLED IN EITHER A VENTED OR UNVENTED
SYSTEM
IMPORTANT NOTE: DO NOT SITE THE UNIT IN THE SAME ROOM AS AN
APPLIANCE WITH AN OPEN FLUE OR IN A ROOM FROM WHICH AN
OPEN FLUED APPLIANCE TAKES ITS COMBUSTION AIR, UNLESS THE
www.esavep.com
7 of 42
V 1.9
Do NOT try to install, move or repair the unit yourself – it is NOT
worthwhile running the risk of injury.
The unit must be transported in the vertical position. It can be
tilted up to 60° from the horizontal axis (see section 11.3).
PASHW-003-100LD