Setting the beep volume
Set the beep volume with the volume switch.
Low volume
(Approx. 70 dB)
NOTE
The beep mode setting is configured while the assembly qualifier is connected to a
computer. See page 7.
Using the software
1. Turn on the assembly qualifier's power switch.
All indicators will turn on and off, leaving only the power
indicator on.
2. Use the registered tool to perform fastening work.
Status of tool's fastening
confirmation indicator
Green
Red
Finishing work
Turn off the assembly qualifier's power switch.
I/O connector
OFF
High volume
(Approx. 85 dB)
Assembly qualifier
indicators
Fastening PASS
indicator
Fastening FAIL
indicator
Pin no.
1
Reset input pin (input)
Reset input pin (common)
3
Relay output pin (common)
4
Relay output pin (fastening PASS)
5
Relay output pin (fastening FAIL)
- 11 -