After recharge, check pressures. Refer to Table A for corresponding temperatures and
pressures. If pressures or temperatures are incorrect, check the sealed system, recover the
charge, repair, evacuate, and then recharge.
NOTE: It is not uncommon to have some condensation or a slight frost on the suction
line. This may occur towards the end of the production cycle. Liquid refrigerant is not
getting into the compressor if the unit was charged properly. It is important that the
insulation remains on the suction line and the capillary tube together after any repair and
that it is sealed at both ends.