Preventative Maintenance - FAMOS F220DEP Manual

Roto sealer f 220 series
Table of Contents

Advertisement

Available languages

Available languages

Preventative maintenance

In order to guarantee an optimal functioning of the rotary sealer and in order to prevent corrective
maintenance, we advise to have the machine checked and cleaned at least twice a year. During this
inspection the following parts are checked on wear and if necessary replaced.
-
12.210.367
-
12.014.015
-
30.200.039
-
30.200.041
-
29.440.016
For the article numbers and descriptions of all other parts we refer to your dealer and/or to the
technical documentation.
Technical data
- Temperature range
- Running speed
- Seal seam width
- Sealing force
- Fuses
- Power consumption
- Main voltage
- Dimensions
- Weight
To avoid the risk of electric chock do not open the casing of the sealer.
Repairs should be undertaken by specialists only.
99.900.121 rev.:1
Transportbelts
Printer pressure roller
Teflon strip on heating elements
Teflon strip on guiding bars
Ribbon cassette
: 100 - 200 °C
: 8 m/min
: 15 mm.
: 10 Kg (internal adjustable 1 - 12 Kg)
: 3 x 3.15AT, 2 x 1AT
: max. 365 W, average 180 W
: 220/240VAC 50/60Hz.
: 560x320x210 mm
: 19,5 Kg
Warning
58

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for FAMOS F220DEP

This manual is also suitable for:

F220dbc

Table of Contents