43
40. Top roller
41. Bottom roller
43. Exit roller (removable)
45. Fixed exit roller
FOLD AREA
The top roller (40) can be cleaned after it has been
removed. With the top roller removed, the bot-
tom roller (41) can be rotated by hand in both
directions to reach the whole surface. The bottom
roller should be thoroughly cleaned all the way
around. This is critical to proper operation.
EXIT END
The removable exit roller (43) can be cleaned
41
outside the machine. The fixed exit roller (45)
can be rotated on its axle by hand. It will also
move when one of the fold rollers is rotated.
Either way, the whole surface of the fixed exit
roller can be exposed.
3. Allow all surfaces to dry before reassembling
the components and closing the access panels.
CAUTION
Do not use strong solvents in the cleaning
45
process. The compounds in the rollers may be
damaged.
NOTE
Whenever the HF-400 is opened to clear paper
jams, it is a good idea to look at the rollers and
clean them if needed.