Arcam FMJ P7 Service Manual page 32

7-channel amplifier
Hide thumbs Also See for FMJ P7:
Table of Contents

Advertisement

1
PRIMARY
6 WAY CONN PIN 3
BROWN
D
100V ac
6 WAY CONN PIN 1
WHITE
6 WAY CONN PIN 6
BLACK
100V ac
6 WAY CONN PIN 4
BLUE
Voltage on Reservoir Capacitor
Vout1 = 22V
C
Vout2 = 9.5V
60 max
B
CENTRE TO BE POTTED AND DRILLED
OUT TO 6mm DIA
COUNTERBORE DIA 12mm
A
COUNTERBORE DEPTH 12mm
Rubber insulating pad
1
2
SECONDARY
RED
4 WAY CONN PIN 3
ORANGE
4 WAY CONN PIN 4
YELLOW
4 WAY CONN PIN 2
PURPLE
4 WAY CONN PIN 1
TEST CIRCUIT (PER OUTPUT)
1N4003
10mS
1N4003
90mm
PRIMARIES
SECONDARIES
110mm
DRAWING TITLE
AUX TOROIDAL TRANSFORMER P7 100V (JAPAN)
23425
Notes:
A & R Cambridge Ltd.
Pembroke Avenue
Denny Industrial Centre
Waterbeach
Filename
Cambridge CB5 9PB
J:\Development_Projects\P7_Amp\Transformer Design\L921tx_1.ddb - Documents\L921TX_1.Sch
2
TEST CIRCUIT
VOUT 1
1N4003
1N4003
500mA load
+
3300uF
1N4003
1N4003
VOUT 2
GND
1N4003
+
150mA load
1000uF
1N4003
GND
6 way MOLEX 39-01-2065
UL94-V0
4 way MOLEX 39-01-3048
6
5
4
4
3
3
2
1
2
1
6 way
4 way
Pin outs of Molex connectors
As viewed looking down at the end
the wires enter the connector
Circuit Diagram
ECO No.
3
Transformer Specification For 100V (JAPAN) P7 Auxilliary Transformer
Arcam Part Number L921TX
Material Safety Specification
1. Winding Wire to be Grade 2 (130C rating) to BS 60317-4 1995
2. Mylar Polyester Insulator 130C Rated
3. Potting Compound PC3502 E135297(M)
Mechanical Specification
1. Middle of transformer to be potted. Potting to be drilled out with an 6mm DIA Hole
and then the bottom surface counterbored to a depth of 12mm with a 12mm dia drill
as shown. Actual part which the counterbore is designed to clear extends up to 10mm from
transformer mounting surface into counterbore.
2. Primary windings connect to 6 way MOLEX 39-01-2065. Secondary
windings connect to 4 way molex connector 39-01-3048. Use MOLEX pin 44476-3112.
MOLEX connectors have pin numbers indicated on them.
3. Use 24 AWG wire with colours as shown. Primary wires are enclosed in a common
sleeve. Secondary wires are enclosed in a common screen. Use PVC sleeving.
4. All wire lengths in mm. Lengths are +5.0, -0
5. Please adhere rubber insulating pad to bottom of transformer as shown.
Electrical Specification
1. Transformer to have dual 100V primaries to allow parallel operation for
100V input.
2. Transformer input voltage range
100V -18% +14% (82V to 114V)
3. Transformer to have two secondary windings as show in the adjacent drawing.
4. Loaded DC voltages specified at 100V AC in (with transformer primaries in parallel)
DC supplies to be generated by configuring the seconday windings with a full wave bridge
(see diagram).
Output Capacitance to be 3300uF. 22V dc
Output Capacitance to be 1000uF. 9.5V dc
VOUT1 = 22.0V dc @ Io = 250mA (With 100V AC in)
V0UT2 = 9.5V dc @ Io = 150mA (With 100V AC in)
(this will ensure that VOUT2 is 8V at 82V AC in)
KAL
05/03/2002
Based on spec of 115/230V part (L912TX)
INITIALS
DATE
DESCRIPTION OF CHANGE
Drawn by:
Date Printed
Sheet
1
KAL
6-Mar-2002
3
4
D
C
B
A
1
ISSUE
of
1
L921TX
DRAWING NO.
4