4. Manual Adjustment
Manual Adjustment
1. TRK. Offset
2. Focus Gain
3. TRK. Gain
4. Focus Offset
5. Focus Balance
6. L.F. Offset
7. EQ BOOST
8. GD ADJ
Adjustment : Up/Down
Jitter 1D
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted manually. Select the
[1]
[8]
desired number
to
from the remote commander, and cur-
rent setting for the selected item will be displayed, then increase
or decrease numeric value with ↑ key or ↓ key. This value is
stored in the EEPROM. If CLV has been applied, the jitter is dis-
played for reference for the adjustment.
[1]
TRK. Offset
Adjusts tracking offset.
[2]
Focus Gain
Adjusts focus gain.
[3]
TRK. Gain
Adjusts track gain.
[4]
Focus Offset
Adjusts focus offset.
[5]
Focus Balance
Adjusts focus balance.
[6]
L.F. Offset
Adjusts loop filter offset.
[7]
EQ BOOST
[8]
GD ADJ
5. Auto Adjustment
Auto Adjustment
1. Auto TRK. Offset
2. Auto Focus Balance
3. Auto Focus Offset
4. Auto Focus Gain
5. Auto TRK. Gain
6. Auto EQ
7. Auto L.F. Offset
8. Auto Group Delay
SA.------ SI.-- EMG. 00
DVD SL 12 cm
On this screen, each item can be adjusted automatically. Select the
[1]
[8]
desired number
to
from the remote commander, and se-
lected item is adjusted automatically.
[1]
Auto TRK. Offset
Adjusts tracking offset.
[2]
Auto Focus Balance Adjusts focus balance.
[3]
Auto Focus Offset
Adjusts focus offset.
[4]
Auto Focus Gain
Adjusts focus gain.
[5]
Auto TRK. Gain
Adjusts track gain.
http://getMANUAL.com
[6]
[7]
[8]
6. Memory Check
EEPROM DATA 1
Focus Gain
TRK. Gain
FCS Balance
Focus Bias
TRV. Offset
L.F. Offset
EQ Boost
Mirror Time
_
DOWN : Next Data
CLEAR: Default Set
EEPROM DATA 2
RF Jitter
RF Level
FE Level
FE Balance
TRV. Level
Analog FRSW
PLL Dac Gain xx xx
_
UP : Prev Data
CLEAR: Default Set
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR]
initialization.
Before clearing the adjusted data, make a note of the set data. This
screen will also appear if
Adjustment. In this case, default setting cannot be made.
For reference, the drive has been designed so that the gain center
value is 20 and offset value is 80. Other values will be in a range
of 10 to 80. If extreme value such as 00 or FF is set, adjustment
will be faulty. In such a case, check for disc scratch or cable dis-
connection, then perform adjustment again.
6-9
Auto EQ
Auto L.F. Offset
Adjusts loop filter offset.
Auto Group Delay
-– DL -–
CD LCD
SL
xx xx
xx
xx xx
xx
xx xx
xx
xx xx
xx
xx xx
xx
xx xx
xx
xx xx
xx
xx --
xx
page. 1/2
-– DL -–
CD LCD
SL
xx --
xx
xx --
xx
xx --
xx
xx --
xx
xx --
xx
xx xx
xx
xx
page. 2/2
key, but be careful that they are not recoverable after
[0]
All is selected in the Drive Auto
L0
L1
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
xx
L0
L1
xx
xx
--
--
--
--
--
--
--
--
xx
xx
xx
xx

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmt-d140aDvp-ns900vRmt-d140pRmt-d140e

Table of Contents