Installation Instructions; Choosing Proper Location For Unit; Roof Preparation - Dometic BR342 Installation And Operating Manual

Air conditioning roof unit
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

A.

Choosing Proper Location For Unit

7KLV XQLW LV VSHFL¿FDOO\ GHVLJQHG IRU LQVWDOODWLRQ RQ WKH URRI
of a recreational vehicle (RV). When determining your
cooling requirements, the following should be considered:
Size of RV;
Window area (increases heat gain);
Amount of insulation in walls and roof;
Geographical location where the RV will be
used;
Personal comfort level required.
1. 1RUPDO ORFDWLRQV7KH XQLW LV GHVLJQHG WR IW RYHU DQ H[
isting roof vent opening.
2. Other locations-When no roof vent is available or an-
other location is desired, the following is recommen-
ded:
a. For one unit installation: The unit should be
mounted slightly forward of center (front to
back) and centered from side to side.
b. For two unit installations: Install one unit 1/3
and one unit 2/3's from front of RV and cen-
tered from side to side.
,W LV SUHIHUUHG WKDW WKH XQLW EH LQVWDOOHG RQ D UHODWLYHO\ ÀDW
and level roof section measured with the RV parked on a
level surface. See table below for maximum acceptable tilt.
Model
Number
BR36H70CR
After Location Has Been Selected:
c. Check for obstructions in the area where unit
will be installed. See (FIG. 1).
Dimensions Are Nominal
FIG. 1
282.6mm
720.7mm
457.2mm
Center Line Of Unit
Keep This Area Free Of Obstructions
Max
Tilt
15°
669.9mm
Roof Opening
Front
d. Maintain structural integrity.
Otherwise damage to product and/or RV
could occur.
The roof must be designed to support 59
kg when the RV is in motion. Normally a
90.7kg. static load design will meet this
requirement.
e. Check inside the RV for air distribution box
obstructions (i.e. door openings, room di-
YLGHUV FXUWDLQV FHLOLQJ ¿[WXUHV HWF  6HH
(FIG. 2).
FIG. 2
581mm
35mm
Dimensions Are Nominal
265mm
65mm
Roof Opening
65mm
152mm
B.

Roof Preparation

1.
HAZARD.
Verify there are no obstacles inside
RV's roof and/or walls (wires, pipes, etc.). Shut
OFF gas supply, disconnect 240Vac power from
RV and disconnect positive (+) 12 Vdc terminal
from supply battery BEFORE drilling or cutting
into RV. Failure to obey these warnings could
result in death or serious injury.
O pening Requirements - Before prepar-
ing the ceiling opening, read all of the fol-
lowing instructions.
If an existing roof vent opening will NOT
be used a roof opening MUST be cut
through the roof and ceiling of the RV.
This opening MUST be located between
the roof reinforcing members.
4
530mm
265mm
530mm
28.6mm
FIRE OR ELECTRICAL SHOCK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents