VAT Series 651 Installation, Operating, & Maintenance Instructions page 41

Pendulum control & isolation valve
Table of Contents

Advertisement

19. Release the valve from safety mode.
Refer to «Safety mode» for details
20. Move the valve to position 50% (half
opened) This is necessary, in order
to dismount the actuator. See step
24.
21. Disable PFO option feature via
'Power Fail Status' in menu 'System'
of CV or CPA software, and turn off
the power
22. Disconnect 24VDC power. Wait for
60s, then disconnect cable and
compressed air from valve actuator.
23. Unfasten all 4 controller screws and
lift controller carefully from actuator.
24. Unfasten all 3 actuator screws and
remove actuator.
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 651 DN 320-400 (I.D. 12" - 16"), Logic
D e s c r i p t i o n
Required tool
• CV software
• CPA software
or
• Service Box 2
Allen Wrench
4 mm
Allen Wrench
5 mm
267736ED
41/53
2008-02-26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents