Logic Interface - VAT Series 651 Installation, Operating, & Maintenance Instructions

Pendulum control & isolation valve
Table of Contents

Advertisement

3.10.2.4
Valve speed adjustment
Valve speed effects:
• Response time
Default value is 1000. Adjustment range is from 1 to 1000.
This parameter effects valve plate actuating speed.
Speed adjustment is effective for PRESSURE CONTROL and POSITION CONTROL.
Note: Normally best pressure control response is achieved with max. valve speed. In particular applications it may be of
advantage to have a slower valve response.
Note: OPEN and CLOSE are always done with max. speed.
Adjustment procedure:
1.
Use optimal gain factor, sensor delay time and setpoint ramp according to preceding tuning steps.
2.
Open valve.
3.
Control a typical pressure / flow situation.
4.
Repeat from step 2 with slower valve speed until required response is achieved.
('Control View', 'Control Performance Analyzer' or
Do configuration in menu 'Setup / Control Parameter'.

3.11 Logic interface

Default configuration:
OPEN input
not inverted
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 651 DN 320-400 (I.D. 12" - 16"), Logic
Local
operation:
'Service Box 2')
CLOSE input
not inverted
Note: It's not possible to do 'Interface configuration'
OPEN output
CLOSE output
open
close
Remote
operation:
via remote operation.
267736ED
2008-02-26
28/53