Quick Links

IDS-409-SFP Hardware Installation Guide
Managed Industrial Ethernet Switches
Updated: October 2016
Revision 1.10
www.perle.com
Document Part#:5500377-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDS-409-SFP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Perle IDS-409-SFP

  • Page 1 IDS-409-SFP Hardware Installation Guide Managed Industrial Ethernet Switches Updated: October 2016 Revision 1.10 www.perle.com Document Part#:5500377-10...
  • Page 2 Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product. Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
  • Page 3: Table Of Contents

    Table of Contents Preface ......................2 Overview .
  • Page 4: Preface

    Preface Audience This guide is for the network or computer technician responsible for installing Perle IDS- 409 series switches. Familiarity with the concepts and terminology of Ethernet and local area networks is required. Purpose This document describes the hardware and physical characteristics of the Perle IDS switch.
  • Page 5: Overview

    Standard 10/100/1000Base-T Temp Models Ports IDS-409-SFP Standard IDS-409-2SFP Standard IDS-409-3SFP Standard IDS-409-5SFP Standard IDS-409-SFP-XT Industrial IDS-409-2SFP-XT Industrial IDS-409-3SFP-XT Industrial IDS-409-5SFP-XT Industrial IDS-409-SFP Hardware Installation Guide...
  • Page 6: Switch Model Views

    4 – Console Port – USB 11 - Reset / FS (Fast Setup) 5 – DIP switches 12 - Wall Mount Bracket Screw Holes 6 – 10/100/10100 Base-T Ports 13 - DIN Rail Clip 7 – SD Card Slot IDS-409-SFP Hardware Installation Guide...
  • Page 7 11 - SFP Slots 5 – DIP switches 12 - Reset / FS (Fast Setup) 6 – SFP Status LEDs 13 - Wall Mount Bracket Screw Holes 7 – 10/100/1000 Base-T Ports 14 - DIN Rail Clip IDS-409-SFP Hardware Installation Guide...
  • Page 8 4 – Console Port – USB 11 - Reset / FS (Fast Setup) 5 – DIP switches 12 - Wall Mount Bracket Screw Holes 6 – SFP Status LEDs 13 - DIN Rail Clip 7 – 10/100/1000 Base-T Ports IDS-409-SFP Hardware Installation Guide...
  • Page 9 4 – Console Port – USB 11 - Reset / FS (Fast Setup) 5 – DIP switches 12 - Wall Mount Bracket Screw Holes 6 – SFP Status LEDs 13 - DIN Rail Clip 7 – 10/100/1000 Base-T Ports IDS-409-SFP Hardware Installation Guide...
  • Page 10: Led Indicators

    Alarms configured, but no alarms detected Alarm condition detected Red - solid Red - blinking Alarm condition detected and Alarm Relay activated BC (Backup Coupling) State Description Backup Coupling not enabled Green - solid Backup Coupling Link enabled IDS-409-SFP Hardware Installation Guide...
  • Page 11 Green - flashing Ring Master unable to establish a ring due to missing link on one of the Ring ports Yellow - solid Ring Master Active, redundant port unblocked - indi- cates a break in the Ring IDS-409-SFP Hardware Installation Guide...
  • Page 12: Ports

    100 or 1000 Mb/s through twisted pair (UTP) cables of up to 100 meters (328ft) in length. 100/1000 Mb/s SFP Slots The SFP slots can accommodate industry standard SFP’s from Perle or other suppliers. These SFP’s can be 100 or 1000 Mb/s or can be SGMII models including 1000Base-T Copper SFP’s.
  • Page 13: Port Status Indicators

    10 Mbps On solid Port Link Random blinking Port Link and Activity Slow blinking Error disabled Rapid blinking Port in Fast Setup Mode SFP Port Status Indicators Port Link State Description Green Link Green Flashing Link/Activity IDS-409-SFP Hardware Installation Guide...
  • Page 14: Terminal Block Connectors

    P2 - Power Input 2 IN 1 - Digital Input 1 - Dry Contact IN 2 - Digital Input 2 - Wet Contact R - Relay with 2 connection points - Normally Open (NO) / Normally Closed (NC) IDS-409-SFP Hardware Installation Guide...
  • Page 15: Dip Switches

    Coupling: Backup on Port 4 (Note 1) Client Primary Ring Feature: enabled Ring Role: Client Coupling: none Note 1: If the backup coupling feature is not used, then port 4 can be used as a normal connection port. IDS-409-SFP Hardware Installation Guide...
  • Page 16 Port Assignment Ring Ports 1, 2 Coupling Port Note: DIP switches are read during system boot up. If a DIP switch is changed the IDS switch must be rebooted in order for the change to take effect. IDS-409-SFP Hardware Installation Guide...
  • Page 17: Installation

    Ensure that voltage and current supplied by the alarm circuits are within the stated Alarm Relay specifications. Warning: In hazardous location installations, failure to remove from the source prior to completing the wiring connections to the alarm relay could cause an electrical arc resulting in a possible explosion. IDS-409-SFP Hardware Installation Guide...
  • Page 18: Terminal Block-Power Connectors

    Warning: In case of malfunction or damage, no attempts at repair should be made. Do not dismantle the product. All repairs need to be made by a qualified Perle representative. Warning: Explosion hazard. Do not remove or replace lamps, fuses or plug-in modules (as applicable) unless power has been disconnected or the area is free of ignitable concentrations.
  • Page 19: Wiring The Relay Alarm

    Alarm Relay specifications. Warning: In hazardous location installations, failure to remove the power from the source prior to completing the wiring connections to the alarm relay could cause an electrical arc resulting in a possible explosion. IDS-409-SFP Hardware Installation Guide...
  • Page 20: Wiring Digital Inputs

    Digital Input specifications. Warning: In hazardous location installations, failure to remove the power from the source prior to completing the wiring connections to the alarm relay could cause an electrical arc resulting in a possible explosion. IDS-409-SFP Hardware Installation Guide...
  • Page 21: Connecting The Console Port

    This could cause an explosion when installed in a hazardous location. Ensure the power is removed from all devices prior to making the cable connection. IDS-409-SFP Hardware Installation Guide...
  • Page 22 This could cause an explosion when installed in a hazardous location. Ensure the power is removed from all devices prior to making the cable connection. IDS-409-SFP Hardware Installation Guide...
  • Page 23: Connecting Data Ports

    SFP module in. SFP modules are keyed so you can only insert them one way. 3. If the SFP module is equipped with a clasp, ensure the clasp is in the locked position. 4. The appropriate fiber cable can now be connected to the SFP module. IDS-409-SFP Hardware Installation Guide...
  • Page 24: Resetting The Switch

    The Reset/Fast Setup button is located near the bottom of the switch. A small tool such as a paper clip is needed to access the recessed button. Soft Reset To reset/restart the switch you can perform a soft reset. Press and immediately release the reset button to perform a soft reset. IDS-409-SFP Hardware Installation Guide...
  • Page 25 When first applying power to the IDS switch, it will startup and go through the boot pro- cess. The LEDs will behave according to the table below. Behavior Yellow during the booting process. Once the system software has been loaded, the PWR LED will reflect the status of the power inputs. IDS-409-SFP Hardware Installation Guide...
  • Page 26 When the switch is not in factory default, the "Fast Setup Mode" sequence will activate Password recovery. Note: The password recovery feature can be disabled in the software. Behavior On solid - during reset process Off - to indicate that reset has completed IDS-409-SFP Hardware Installation Guide...
  • Page 27: Configuring The Ids Switch

    Web Device Manager The Perle Web Device Manager is an embedded Web based application that provides an easy to use browser interface for managing the switch. This interface provides the ability to configure and manage the switch. This is accessible through any standard desktop web browser.
  • Page 28: Appendix A - Technical Specifications

    Overload Current Protection Fuse Reverse polarity protection Interfaces 10/100/1000Base-T (RJ45) • Up to 100 meters (328 ft.) • Auto-negotiation • Auto-MDI/MDIX • Ethernet isolation 1500 V SFP Slot • 100/1000Base-X MSA compliant SFP’s • Also supports SGMII SFP’s IDS-409-SFP Hardware Installation Guide...
  • Page 29 IEC/EN 61000-4-4 (EFT) IEC/EN 61000-4-5 (Surge) IEC/EN 61000-4-6 (CS) IEC/EN 61000-4-8 (Magnetic Field) IEC/EN 61000-6-2 (General Immunity in Industrial Environments) Hazardous Locations (Hazloc) ANSI/ISA 12.12.01, Class 1 Division 2 Groups A-D* ATEX Zone 2 * * pending IDS-409-SFP Hardware Installation Guide...
  • Page 30 Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. www.perle.com/support_services/support_request.shtml Warranty / Registration This product is covered by the Perle Ethernet Switches Warranty. Details can be found at: https://www.perle.com/support_services/warranty.shtml IDS-409-SFP Hardware Installation Guide...
  • Page 31: Appendix B - Sample Labels

    Appendix B - Sample Labels Appendix B - Sample Labels IDS-409-SFP Hardware Installation Guide...
  • Page 32: Appendix C - Mechanical Drawings

    Appendix C - Mechanical Drawings Appendix C - Mechanical Drawings IDS-409-SFP Hardware Installation Guide...
  • Page 33 Appendix C - Mechanical Drawings IDS-409-SFP Hardware Installation Guide...
  • Page 34 Appendix C - Mechanical Drawings IDS-409-SFP Hardware Installation Guide...
  • Page 35 Appendix C - Mechanical Drawings IDS-409-SFP Hardware Installation Guide...
  • Page 36: Appendix D - Din Rail And Wall Mounting

    2. Insert a flat blade screwdriver into the slot and twist the base to release the clip. Alter- natively a downward force on the clip will release the clip. 3. When the clip is released, pull the bottom of the switch out slightly and remove the switch from the DIN rail. IDS-409-SFP Hardware Installation Guide...
  • Page 37 6. Pull the IDS switch down to lock the IDS switch to the wall mount. 7. Tighten the four screws securely to the wall. Note: for best results use screws with the following attributes Head diameter .5 - .6 mm Shaft diameter 3 -3.5 mm IDS-409-SFP Hardware Installation Guide...
  • Page 38: Appendix E - Ids Maintenance

    Do not use solvents or cleaning agents on this unit • Keep vent holes clear of debris • If case gets dirty wipe with a dry cloth • Ensure all cables are in good working condition • Replace any frayed cables or cables without clips IDS-409-SFP Hardware Installation Guide...
  • Page 39: Appendix F - Cables And Connectors

    Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port. Requirements: • Cat 5 UTP or STP, Cat 5e cables • 24-22 AWG (0.20mm - 0.33mm • Straight through or Ethernet Crossover cable IDS-409-SFP Hardware Installation Guide...
  • Page 40 Appendix F - Cables and Connectors Note: An optional cable adapter is available to provide RJ45 to DB9 conversion: Perle’s optional RJ45 to DB9-F crossover adapter model DB0020C enables a straight through Ethernet cable to connect the RJ45 console port to a PC serial port.