3) Connecting the cords
1. Remove screw
locating at the left-hand side of the power switch.
Place the top end of ground cord (asm.)
detection sensor plate (asm.)
screw has been removed. Then, re-tighten the screw in the tapped
hole so as to secure the ground cord (asm.).
2. In regard to the connection of the cord
control box.
4) Adjusting the knee-lifter detection seat (asm.)
1. Turn ON the power to the machine.
2. Press knee-patch plate
top surface of the throat plate.
3. Turn the knee-lifter sensor seat (asm.)
and secure it with the setscrew
sensor
begins to light. At that time, align the end face of the sensor
seat (asm.)
with that of the knee-lifter sensor
4. Check that the LED goes up when knee-patch plate
(Caution) The machine has been adjusted so that the knee-lifter
actuation is detected when the presser foot goes up by 5
mm or more. To enable the sensor to detect the actuation
of the knee-lifter with a smaller amount of the presser
foot lift, reduce the standard adjustment value and re-
adjust the machine according to step 3.
5. When the magnet of knee-lifter detection seat (asm.)
the detecting section (marked with "+") of knee-lifter detection sensor
, the sensor detects that the presser foot has been raised by the
knee-lifter and the LED of the sensor lights up.
1. Check Dimension A of the thread take-up lever
.
2. If Dimension A is not secured properly, loosen two setscrews
adjustment.
Adjustment Procedure
on the tapped hole from which the
, connect it to [CN32] of the
to raise the presser foot by 5 mm above the
in the direction of the arrow
where the LED of the knee-lifter
Adjustment Procedure
corning from knee-lifter
.
. is released.
approaches
and its thread guide
for
– 55 –
Results of Improper Adjustment
o If the ground cord (asm.)
not connected, maloperation
may be caused.
o If the cord is not connected or
improperly connected to the
control box, the sensor may fail
to perform detection.
o If no coincidence is secured of
the knee-lifter sensor
end plane of the knee-lifter
sensor seat (asm.)
be a cause of failure in sensing.
Results of Improper Adjustment
is
with the
, this can