1x230V, 3x230V and 3x400V
Output data according to EN 14511 nominal
0/35
Rated output
Installed electrical output
COP
0/45
Rated output
Installed electrical output
COP
10/35
Rated output
Installed electrical output
COP
10/45
Rated output
Installed electrical output
COP
SCOP according to EN 14825
Nominal heating output (designh)
SCOP
cold climate 35 °C / 55 °C
EN14825
SCOP
average climate, 35 °C / 55 °C
EN14825
Energy rating, average climate
Efficiency class for space heating 35 °C /
55 °C
Space heating efficiency class of the sys-
1)
tem 35 °C / 55 °C
Efficiency class hot water / charging pro-
file
Sound power level (L
at 0/35
Sound pressure level (L
according to EN ISO 11203 at 0/35 and 1m range
Electrical data
Output, Brine pump
Output, Heating medium pump
IP class
Refrigerant circuit
Type of refrigerant
Volume
Cut-out value pressostat HP
Difference pressostat HP
Cut-out value pressostat LP
Difference pressostat LP
66
Chapter 12 |
Technical data
kW
kW
kW
kW
kW
kW
kW
kW
kW
)
dB(A)
WA
acc to EN 12102
)
dB(A)
PA
calculated values
W
W
kg
MPa
MPa
MPa
MPa
F1255-6
F1255-12
3.15
0.67
4.72
2.87
0.79
3.61
4.30
0.66
6.49
3.98
0.83
4.79
6
5.5 / 4.1
5.4 / 4.3
5.2 / 4.0
5.2 / 4.1
A++ / A++
A++ / A++
A+++ / A+++
A+++ / A+++
A / XL
36 – 43
21 – 28
10 – 87
2 – 63
1.16
-0.7 (-7 bar)
0.15 (1.5 bar)
0.15 (1.5 bar)
F1255-16
5.06
1.04
4.87
4.78
1.27
3.75
6.33
1.03
6.12
5.98
1.30
4.59
12
5.5 / 4.2
5.2 / 4.1
A++ / A++
A+++ / A+++
A / XL
36 – 47
36 – 47
21 – 32
21 – 32
3 – 180
20 – 180
2 – 60
10 – 87
IP21
R407C
2.0
3.2 (32 bar)
8.89
1.83
4.85
8.63
2.29
3.77
11.22
1.84
6.11
10.92
2.32
4.72
16
A / XL
2.2
NIBE™ F1255

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1255 seriesF1255-6F1255-16F1255-12

Table of Contents