4-3.

SERVICE MODE

Note: After the completion of the all adjustments, cancel the service mode
by either of the following ways.
1)
Unplug the main power supply and remove the lithium battery.
(In this case, date and time and menu setting have been set by
users are canceled. Perform resetting.)
2)
After data on page: D and F is restored, return data of the
address: 01 on page: 0 to 00. And when data on page: 2 is
changed, return the data to the original condition.

1. Test Mode Setting

Set/release each test mode. Set page: 0, address: 01, data: 01 before
setting the data of page D and F.
Page F
Address 2C
Data
00
Normal
01
Test mode
Various emergency prohibitions and releases Drum
emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page D
Address 10
Data
00
Normal
01
Camera power ON
02
VTR power ON
03
Camera + VTR power ON
*
For page D and F, the data set will be recorded in the nonvolatile
memory by pressing the PAUSE button on the adjustment
remote commander. Take note that, in this case, the test mode
will not be released even if the main power has been turned
off.
*
Be sure to return this address data to 00 after completing
adjustments/repairs and press the PAUSE button of the
adjustment remote commander. And set page: 0, address: 01,
data: 00.