Color Reproduction Adjustment; Iris In/Out Adjustment - Sony CCD-TR913E Service Manual

Video camera recorder
Hide thumbs Also See for CCD-TR913E:
Table of Contents

Advertisement

6. Color Reproduction Adjustment

Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
4E, 50, FB, FC
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) ..................................... OFF
4) VIDEO LIGHT ................................................................ OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: E1, set data: 1B, and press the PAUSE
button of the adjustment remote commander.
3) Select page: F, address: 27, set data: 3F, and press the PAUSE
button.
4) Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5) Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
6) Change the data of page: F, address: 4E, 50, FB and FC, and
settle each color luminance point in each color reproduction
frame.
Note: Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2) Select page: F, address: E1, set data: 1E, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
Burst position
Fig. 5-1-9.

7. IRIS IN/OUT Adjustment

For the unit to judge if the white balance is indoors or outdoors in
auto white balance operations, measure the light level and write it
in the EEPROM.
If the level is not correct, the white balance will not be accurate.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note: The right four digits of the DDS display data of LCD or TV monitor.
00 XX XX
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) ..................................... OFF
4) VIDEO LIGHT ................................................................ OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 06.
3) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 6, address: 01, set data: 0B, and press the PAUSE
button.
5)
Read the DDS display data (Note), and take the upper two digits
as D
and the lower two as D
1
6)
Convert D
to decimal notation, and obtain D
1
5-4-1. "Hexadecimal - decimal conversion table" of "5-4.
Service Mode".)
7)
Calculate D
' using the following equations. (Equations 1 and
3
2 are for decimal notation calculation).
When D
D0
2
D
' = D
3
When D
< D0
2
D
' = D
3
8)
Convert D
' to hexadecimal notation, and obtain D
3
9)
Select page: F, address: 56, set data: D
button.
10) Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
11) Read the DDS display data (Note), and take the upper two digits
as D
and the lower two as D
4
12) Convert D
to decimal notation, and obtain D
4
5-4-1. "Hexadecimal - decimal conversion table" of "5-4.
Service Mode".)
13) Calculate D
' using the following equations. (Equations 3 and
6
4 are for decimal notation calculation).
When D
F0
5
D
' = D
6
When D
< F0
5
D
' = D
6
14) Convert D
' to hexadecimal notation, and obtain D
6
15) Select page: F, address: 57, set data: D
button.
Processing after Completing Adjustments
1) Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 0, address: 03, and set data: 00.
4) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5-16
Clear chart
(Color reproduction adjustment frame)
DDS display of LCD or TV monitor
(Note)
F
56, 57
Lower two digits
Upper two digits
.
2
'. (Refer to Table
1
' – 21
Equation 1
1
' – 22
Equation 2
1
, and press the PAUSE
3
.
5
'. (Refer to Table
4
' – 13
Equation 3
4
' – 14
Equation 4
4
, and press the PAUSE
6
.
3
.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccd-tr950e

Table of Contents