E 1-6
1.3.
1.3.1.
1.3.2.
•>
ACCESSORIES
Standard
accessories
operating
manual
fuse
and
voltage
labels
2-terminal
test
fixture
Optional
accessories
service
manual
4
-wire
test
cable
RCL
adapter
with
2
single
test
posts
and
1
double
test
post
SMD
test
fixture
9499 520 08201
5322 265 24026,
Fig.
33
By means
of
the 2 -terminal
test
fixture
common
compo-
nents
are
connected
9499 525 00911
PM
9541
,
Fig.
34
PM
9542,
Fig.
35
PM
9542
SMD,
Fig.
36
optional
accessory
for
PM
9542
For
precise results
low-ohmic impedances
<
100
£2
should
be
measured
applying 4
-wire
system.
For
this
the
4-wire
test
cable with
Kelvin
clamps
PM
9541 and
the
RCL
adapter
PM
9542
are available.
PM
9541
is
also ideal
for
in-circuit testing
of
components.
PM
9542
is
designed
to provide rapid
low impedance connection
to
the instrument, whatever the
shape
and dimension
of the
component
under
test.
Please
remove
the
two
single test
posts,
if
you
use the
double
test
post
for
CUT
connection
or
remove
the
double
test
post
if
you
use the
two
single test posts.
Wrong
insertion
of the
plug into
the
RCL
meter
is
prevented by unsymmetrical arrangement of the
pins.
About
compensation
of
the zero
capacitance chapter
3.4.3. gives
some
information.
When
measuring
low-ohmic components
with
PM
9541,
the
short-circuit
inductance
of
max.
0.3 juH of
the cable
must
be
taken
into
account.
PM
9542
SMD
is
designed
for
measurement
of
SMD
components
(Surface
Mounted
Devices).
The
SMD
test
fixture
is
used together with the
RCL
adapter
PM
9542.
For
understanding the
measurement
circuit
when
applying the
accessories, see
figs.
32
-
36.
Performance
characteristics
p"*-
,
A
i
PM
9541
PM
9542
PM
9542
SMD
j
1)
CUT
connection
2 Kelvin
clips
Kelvin contacts within the
test
posts
Kelvin contacts
^
J
short-circuit
inductance
0,1
MH, max.
0.3 /tH
<
0.1
/2H
<
0.1
/iH
.
I
i
:
1
i
:
\
1
f
1
:
.(
measuring accuracy
with
PM
6303
dimensions of
components under
test
-
length
width
height
mechanical
specifications
as
for
PM
6303,
but additional
error for
very
low-ohmic
CUTs
caused
by
the
internal
short-circuit
inductanco
as
for
PM
6303
as for
PM
6303
but
additional error for
CUTs
with very
low
capacitance,
see chap.
3.4.5.
and
Fig.
36a
min. 2
mm/max. 10
mm
min.
1
mm
min.
0.5
mm
i
cable
length
0.6
m
0.6
m
f
dimensions
50
mm
x
1
45
mm
x
95
mm
45
mm
x
55
mm
x
30
mm
i
J
weight
0.2 kg
0.6 kg
0.03
kg
|
1
1
A
;
spare
parts:
none
double
test post:
none
5322
264
30185;
2
single test
posts (red
and
black);
5322
264 30184