Siemens SITRANS LG250 Operating Instructions Manual page 78

Guided wave radar 4...20 ma/hart - two-wire rod and cable probe with sil qualification
Table of Contents

Advertisement

15 mm
(0.591
)
"
2 mm
(0.079
")
0
-2 mm
(-0.079
")
1
-10 mm
(-0.591
")
0,15 m
(5.906
Fig. 40: Deviation SITRANS LG250 in rod version in oil
1
Dead band - no measurement possible in this area
L
Probe length
15 mm
(0.591
")
2 mm
(0.079
")
0
-2 mm
(-0.079
")
1
10 mm
(0.394
")
0,08 m
(3.15
")
Fig. 41: Deviation SITRANS LG250 in cable version in water
1
Dead band - no measurement possible in this area
L
Probe length
78
0,3 m
)
(11.811
"
")
0,3 m
(11.811
")
SITRANS LG250 - Operating Instructions
L
L
1
0,07 m
(2.756
")
0,05 m
(1.97
")
0,1 m
(3.94
")
PBD-51041388