A single-stage thermostat with only one heating stage may be used to control this furnace.
To use a single-stage thermostat, turn off power to the furnace, move the thermostat selection DIP switch to the OFF position. Turn
power back on. Refer to the DIP switch chart in this manual.
24 V
D
W
OLT
EHUMIDISTAT
The optional usage of a dehumidistat allows the furnace's circulator blower to operate at a slightly lower speed (85% of desired speed)
during a combined thermostat call for cooling and dehumidistat call for dehumidification. This can be done through an independent
dehumidistat or through a thermostat's DEHUM terminal (if available). This lower blower speed enhances dehumidification of the
conditioned air as it passes through the AC coil. For proper function, a dehumidistat applied to this furnace must operate on 24 VAC
and utilize a switch which opens on humidity rise. Refer to the "Thermostat Wiring Diagrams" figure for additional wiring
details.
To install/connect a dehumidistat:
1. Turn OFF power to furnace.
2. Secure the dehumidistat neutral wire (typically the white lead) to the terminal marked "DEHUM" on the furnace integrated
control module.
3. Secure the dehumidistat hot wire (typically the black lead) to the terminal marked "R" on the furnace integrated control
module.
4. Secure the dehumidistat ground wire (typically the green lead) to the ground screw on the furnace junction box. NOTE:
Ground wire may not be present on all dehumidistats.
5. If the condenser is a straight cooling unit, install a jumper from Y1 to 0 on the furnace board.
6. Turn ON power to furnace.
To enable the dehumidify function on the integrated control module, set the dehumidification ENABLE DIP switch from OFF to ON.
Once the switch is set, the dehumidify function is enabled during a combination call for cooling (T-Stat) and dehumidification
(DEHUM-Stat). Refer to the DIP switch chart in the back section of this manual.
30
Furnace Integrated
Control Module
NEU
Dehumidistat
[Optional]
Figure 31
W1
W2
Furnace Integrated
W1
W2
Control Module
NEU
Dehumidistat
[Optional]
Figure 33
A
PPLICATION
IRING
IMPORTANT NOTE
T
-
H
T
O USE A SINGLE
STAGE
EAT
FURNACE CONTROL BOARD MUST BE SET TO THE
THERMOSTAT
R
R
Y
C
Remote
Condensing Unit
(Single-Stage Cooling)
Thermostat - Two-Stage Heating with Single-Stage Cooling
Figure 32
IMPORTANT NOTE (COOLING SETUP)
S
DIP
#14
ON
ET
SWITCH
TO
POSITION WHEN USING A
.
COOLING THERMOSTAT
, DIP
#13
HERMOSTAT
SWITCH
OFF
.
POSITION
Furnace Integrated
Control Module
NEU
Dehumidistat
[Optional]
2-
STAGE
ON THE