6 |
·
Do not
drop or place objects (such as tools) on
the modules.
Do not
·
carry modules on your head.
·
Do not
use sharp instruments on the modules.
·
Do not
place modules on top of each other
Do not
·
leave modules unsupported or unsecured.
Do not
·
change the wiring of bypass diodes.
· Keep all electrical contacts clean and dry.
PRODUCT IDENTIFICATION
· Each module is equipped with two identical bar-
codes (one inside the laminate under the front
glass, the second on the rear side of the module)
that act as a unique identifier. Each module has a
unique serial number containing 14 digits.
· A nameplate is also affixed to the rear glass of
each module. This nameplate specifies the model
type, as well as the main electrical and safety cha-
racteristics of the module.
5.0

MODULE INSTALLATION

PRECAUTIONARY MEASURES
AND GENERAL SAFETY
· Prior to installing modules please obtain infor-
mation about any requirements and necessary
approvals for the site, installation and inspection
from the relevant authorities.
· Check applicable building codes to ensure that
the construction or structure (roof, facade,
support, etc.) can bear the module system load.
· Canadian Solar Inc. double glass solar modules
have been qualified for Application Class A
(equivalent to Safety Class II requirements).
Modules rated under this class should be used in
systems operating at voltage above 50 V or power
above 240 W, where general contact access is
anticipated.
DO NOT STAND OR STEP
Please note
modules under any circumstances.
EN-Rev IM-FDM-EN/1.6 Copyright © March 2017. Canadian Solar Inc.
Localized heavy loads may cause severe micro-
cracks at cell level, which in turn may compromise
module reliability. Failure to comply with the above
caution will void Canadian Solar Inc.'s warranty.
SYSTEM FIRE RATING
· The fire rating for this module is only valid when
the product is installed as specified in the mechani-
cal mounting instructions.
· Canadian Solar Inc. double glass modules
have been certified by CSA as Type 3 for fire
performance.
· When installing the modules on rooftop, please
ensure the assembly is mounted over a fire resistant
roof covering rated for the application.
· A photovoltaic system composed of UL1703
certified modules mounted on a UL2703 certified
mounting system should be evaluated in combina-
tion with roof coverings in accordance with UL1703
standard, with respect to meeting the same fire
classification as the roof assembly.
· Mounting systems with a System Fire Class Rating
(Class A, B or C), tested in conjunction with fire
rated "Type 3" rated modules, are considered ac-
ceptable for use with Canadian Solar Inc. modules,
provides the mounting system does not violate any
other requirements of this manual.
· Any mounting system limitations on inclination or
accessories required to maintain a specific System
Fire Class Rating should be clearly specified in the
installation instructions and UL2703 certification of
the mounting system supplier.
ENVIRONMENTAL CONDITIONS
· The module is intended for use in general open-air
climates, as defined in IEC 60721-2-1: Classification
of environmental conditions Part 2-1: Environmental
conditions appearing in nature - temperature and
humidity.
· Please consult the Canadian Solar Inc. technical
support department for more information on the
on the
use of modules in special climates.